Accuracy Considerations When Using Early (Four- or Six-Hour) Radioactive Iodine Uptake to Predict Twenty-Four-Hour Values for Radioactive Iodine Dosage in the Treatment of Graves' Disease
Authors:
- Alan D. WaxmanAWAlan D. Waxman
- Glenn D. BraunsteinGBGlenn D. Braunstein
- 1 September 2000
- journal article
- research article
- Published by SAGE Publications in Thyroid®
- Vol. 10 (9) , 779-787
Abstract
Although literature has offered methods to predict 24-hour radioactive iodine uptake values from early (4- to 6-hour) measurements, the resultant dosage errors have not been examined. Potential errors include underdosage, overdosage, and a failure to recognize rapid turnover patients (early-to-late uptake ratios ⩾1) who are at high risk for treatment failure and full-body radiation exposure. We developed and tested a novel method for minimizing error involved in using a single early uptake measurement to derive late uptake. From a retrospective analysis of 203 Graves' disease patients, receiver operating characteristic (ROC) curve analysis enabled us to identify patients likely to experience rapid turnover and therefore should receive 24-hour studies. Twenty-four-hour uptake measurements are necessary with 77% or more 4-hour uptake values and 80% or more 6-hour values. After eliminating these patients, we developed linear regression equations to predict the 24-hour uptake from 4-hour (n = 61) and 6-hour (n = 22) rule groups, testing their efficacy on separate 4-hour (n = 61) and 6-hour (n = 21) patient groups. We also used our test population to measure error in four earlyto- late uptake conversion formulas presented in the literature. Error involved in these predictions ranged from a 10.6% overestimate for 4-hour calculations to a 5.9% underestimate for 6-hour calculations. When applied to two dosage formulas incorporating gland size, absorbed dose, and 24-hour uptake, average dosage error was 7%. In comparison to the other sources of error radioactive iodine (131I) dosimetry, potential error in predicting 24-hour uptake from 4- or 6-hour uptake values is low.Keywords
This publication has 28 references indexed in Scilit:
- Thyroid Nodules in the Follow-Up of Irradiated Individuals: Comparison of Thyroid Ultrasound with Scanning and PalpationThe Journal of Clinical Endocrinology & Metabolism, 1997
- Clinical outcome of radioiodine treatment of hyperthyroidism: a follow-up studyJournal of Internal Medicine, 1996
- Is calculation of the dose in radioiodine therapy of hyperthyroidism worth while?Clinical Endocrinology, 1995
- Standardized radioiodine therapy in Graves' disease: the persistent effect of thyroid weight and radioiodine uptake on outcomeJournal of Internal Medicine, 1994
- Thyroid incidentalomas. Prevalence by palpation and ultrasonographyArchives of internal medicine (1960), 1994
- Radioiodine Turnover Studies as a Means to Predict Stable Intrathyroidal Iodine Stores and Comments upon Its Use in the Diagnosis and Treatment of HyperthyroidismThyroid®, 1993
- Clinical Diagnostic Potentials of Thyroid Ultrasonography and Scintigraphy: an Evaluation.Endocrine Journal, 1993
- Results of 131I Theory for 2000 Thyrotoxic Patients: Do the Effects Depend on the Dose?Experimental and Clinical Endocrinology & Diabetes, 1991
- Long‐term follow‐up of treatment of thyrotoxicosis by three different methodsClinical Endocrinology, 1991
- Treatment of Thyrotoxicosis with Radioactive IodineBMJ, 1955