New Dimensions in Renal Transplant Sonography
- 1 June 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Transplantation
- Vol. 101 (6) , 1344-1352
Abstract
Background The aim of this study is to demonstrate the usefulness of adding 3-dimensional (3D) ultrasound in evaluation of renal transplant vasculature compared to 2-dimensional (2D) Duplex ultrasound. Methods One hundred thirteen consecutive renal transplant 2D and 3D ultrasound examinations were performed and retrospectively reviewed by 2 board-certified radiologists and a radiology resident individually; each reviewed 2D and then 3D images, including color and spectral Doppler. They recorded ability to visualize the surgical anastomosis and rated visualization on a subjective scale. Interobserver agreement was evaluated. Variant anastomosis anatomy was recorded. Tortuosity or stenosis was evaluated if localized Doppler velocity elevation was present. Results The reviewers directly visualized the anastomosis more often with 3D ultrasound ( =97.5%) compared with 2D ( =54.5%) [difference in means (DM) = 43% (95% confidence interval (CI) = 36%-50%) (P < 0.001)]. The reviewers visualized the anastomosis more clearly with 3D ultrasound (P < 0.001) [difference in medians = 0.5, 1.0, and 1.0, (95% CI = 0.5-1.0, 0.5-1.0, and 1.0-1.5)]. Detection of variant anatomy improved with 3D ultrasound by 2 reviewers [DM = 7.1% and 8.9% (95% CI = 1%-13% and 4%-14%, respectively) (P < 0.05)]. There was high interobserver agreement [ = 95.3%, (95% CI = 91.9%-98.7%) regarding anastomosis visualization among reviewers with wide-ranging experience. Conclusions Direct visualization of the entire anastomosis was improved with 3D ultrasound. Three-dimensional evaluation improved detection of anatomic variants and identified tortuosity as the likely cause of borderline localized elevation in Doppler velocity. The data added by 3D ultrasound may obviate confirmatory testing with magnetic resonance angiography or computed tomographic angiography after equivocal 2D ultrasound results.Keywords
This publication has 21 references indexed in Scilit:
- Imaging of Pediatric Renal Transplants and Their Complications: A Pictorial ReviewRadioGraphics, 2013
- Imaging of Renal Transplant: Utility and Spectrum of Diagnostic FindingsCurrent Problems in Diagnostic Radiology, 2011
- Imaging For Renovascular DiseaseSeminars in Nephrology, 2011
- Color duplex sonography in severe transplant renal artery stenosis: a comparison of end-to-end and end-to-side arterial anastomosesClinical Imaging, 2009
- Impact of 3D Sonography on Workroom Time EfficiencyAmerican Journal of Roentgenology, 2007
- Surgical Complications After Kidney TransplantationSeminars in Dialysis, 2005
- Vascular and nonvascular complications of renal transplants: Sonographic evaluation and correlation with other imaging modalities, surgery, and pathologyJournal of Clinical Ultrasound, 2005
- Duplex Doppler sonography of transplant renal artery stenosisJournal of Clinical Ultrasound, 2003
- Vascular imaging with a three-dimensional power Doppler system.American Journal of Roentgenology, 1995
- Short- and Long-Term Outcomes of Kidney Transplants with Multiple Renal ArteriesAnnals of Surgery, 1995