Clinical Outcomes After Coronary Bioadaptor Versus Drug-Eluting Stent Implantation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
Authors:
- Konrad JabłońskiKJKonrad Jabłoński
- Grzegorz ProcykGrzegorz Procyk
- Patrycja Sandra ZawadzkaPZPatrycja Sandra Zawadzka
- Stanisław FelisSFStanisław Felis
- Radosław PastuszekRPRadosław Pastuszek
- Aleksandra FerencAFAleksandra Ferenc
- Kristina VidenovaKVKristina Videnova
- Klaudia PachulskaKPKlaudia Pachulska
- Zenon HuczekZHZenon Huczek
- Aleksandra GąseckaAleksandra Gąsecka
Open Access
- 26 November 2026
- journal article
- review article
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16 (12) , 594
Abstract
Background/Objectives: The bioadaptor represents a novel alternative to drug-eluting stents (DESs) for percutaneous coronary intervention (PCI). We aimed to synthesize and critically appraise randomized evidence comparing bioadaptors with contemporary DES with regard to clinical outcomes. Methods: We searched PubMed, Embase, Scopus, MEDLINE Ultimate, and Web of Science through 9 September 2026 for randomized controlled trials (RCTs) enrolling adult patients undergoing PCI with either a bioadaptor or DES. Risk of bias was assessed using the RoB 2 tool. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiovascular death, target vessel myocardial infarction, and clinically driven target lesion revascularization. Secondary endpoints included the individual components of TLF, device thrombosis, patient-oriented composite endpoint, all-cause mortality, clinically driven target vessel revascularization, non-target vessel myocardial infarction (NTV-MI), and stroke. Results: Three RCTs met the inclusion criteria, of which two were included in the quantitative synthesis. The primary analysis comprised 2835 patients. At 12-month follow-up, no significant difference in TLF was observed between bioadaptors and DES (RR: 0.82, 95% CI: 0.51–1.30). No statistically significant differences were observed for any of the pooled secondary endpoints. Pooled estimates for NTV-MI and stroke could not be calculated because of non-estimable risk ratios. The certainty of evidence ranged from low to moderate across the evaluated outcomes. Conclusions: The available randomized evidence shows no statistically significant differences between bioadaptors and contemporary DES in clinical outcomes at 12-month follow-up. However, the certainty of evidence ranges from low to moderate, warranting cautious interpretation of these findings.Keywords
This publication has 23 references indexed in Scilit:
- DYNAMX Bioadaptor Implantation for Treatment of Complex Coronary Artery Disease: The DYNAMITE StudyThe American Journal of Cardiology, 2026
- First randomised controlled trial comparing the sirolimus-eluting bioadaptor with the zotarolimus-eluting drug-eluting stent in patients with de novo coronary artery lesions: 12-month clinical and imaging data from the multi-centre, international, BIODAPTOR-RCTeClinicalMedicine, 2023
- 24-Month Clinical Follow-Up and Mechanistic Insights From Intravascular Imaging Following Coronary Implantation of the Novel DynamX Bioadaptor PlatformCardiovascular Revascularization Medicine, 2022
- Adaptive Coronary Artery Rotational Motion Through Uncaging of a Drug-Eluting Bioadaptor Aiming to Reduce Stress on the Coronary ArteryCardiovascular Revascularization Medicine, 2022
- Bioresorbable stents: Is the game over?International Journal of Cardiology, 2022
- Stent-Related Adverse Events >1 Year After Percutaneous Coronary InterventionJACC, 2020
- Time-Varying Outcomes With the Absorb Bioresorbable Vascular Scaffold During 5-Year Follow-upJAMA Cardiology, 2019
- The Current Literature on Bioabsorbable Stents: a ReviewCurrent Atherosclerosis Reports, 2019
- Coronary artery rotation in native and stented porcine coronary arteriesCatheterization and Cardiovascular Interventions, 2017
- The TWENTE Trial in PerspectiveJAMA Cardiology, 2017