Abstract
Purpose: Difficulties in sterilizing impressions have led to chemical disinfection solutions as an alternative; however, some impression materials are more sensitive to humidity. For example, polyether impression materials are more hydrophilic. This study investigated the effect of three disinfecting methods on the dimensional stability of three polyether impression materials. Materials and Methods: Three polyether impression materials (P2, Impregum Penta Soft, and Impregum Penta) were submitted to the following treatments: spray disinfectant (Mikrozid Liquid), immersion in 2% glutaraldehyde solution (Super‐On), immersion in 0.525% sodium hypochlorite solution for 10 minutes, and a control group (not disinfected). Each group included five samples. After treatment, dimensional change was evaluated according to ISO 4823. The data were analyzed by 2‐way analysis of variance at α= 0.05. Results: The mean percentages of linear dimensional change of materials P2, Penta Soft, and Penta were –0.040%, 0.098%, and 0.100%, respectively. The dimensional change associated with different disinfectant agents mikrozid liquid, 2% glutaraldehyde, room air (control), and 0.525% sodium hypochlorite was 0.013%, 0.024%, 0.077%, and 0.096%, respectively. The interaction between the impression materials and the disinfectant treatment was not significant. The disinfectant agents can be classified in two groups as low‐ and high‐effected. The control group did not significantly differ from either group. Conclusion: From the standpoint of dimensional change, the disinfectants tested for 10 minutes caused no significant linear dimensional change in the polyether impression materials, compared with the control group.Keywords
This publication has 21 references indexed in Scilit:
- Effects of chemical disinfectant solutions on the stability and accuracy of the dental impression complexThe Journal of Prosthetic Dentistry, 1996
- Dimensional stability of seven elastomeric impression materials immersed in disinfectantsThe Journal of Prosthetic Dentistry, 1996
- Surface characteristics of polyether and addition silicone impression materials after long-term disinfectionThe Journal of Prosthetic Dentistry, 1995
- Three-dimensional investigation of the accuracy of impression materials after disinfectionThe Journal of Prosthetic Dentistry, 1993
- Carriage of oral flora on irreversible hydrocolloid and elastomeric impression materialsThe Journal of Prosthetic Dentistry, 1991
- The presence and identification of organisms transmitted to dental laboratoriesThe Journal of Prosthetic Dentistry, 1990
- Effects of disinfectants on dimensional accuracy of impression materialsThe Journal of Prosthetic Dentistry, 1990
- The dimensional stability of elastomeric impression materials following disinfectionThe Journal of Prosthetic Dentistry, 1990
- Linear dimensional changes in dental impressions after immersion in disinfectant solutionsThe Journal of Prosthetic Dentistry, 1988
- An overview of infection control in dental practiceThe Journal of Prosthetic Dentistry, 1988