Advances in Small Pixel TES-Based X-Ray Microcalorimeter Arrays for Solar Physics and Astrophysics
- 11 January 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 2100705
Abstract
We are developing small-pixel transition-edge sensor microcalorimeters for solar physics and astrophysics applications. These large format close-packed arrays are fabricated on solid silicon substrates and are designed to have high energy resolution, and also accommodate count-rates of up to a few hundred counts per second per pixel for X-ray photon energies up to ~ 8 keV. We have fabricated kilo-pixel versions that utilize narrow-line planar and stripline wiring. These arrays have a low superconducting transition temperature, which results in a low heat capacity and low thermal conductance to the heat sink. We present measurements of the performance of pixels with single 65-μm absorbers on a 75-μm pitch. With individual single pixels of this type, we have achieved a full-width at half-maximum energy resolution of 0.9 eV with 1.5 keV Al K X-rays, to our knowledge the first X-ray microcalorimeter with sub-eV energy resolution. We will discuss the properties of these arrays and their application to new solar and astrophysics mission concepts.Keywords
This publication has 16 references indexed in Scilit:
- Implications of Weak Link Effects on Thermal Characteristics of Transition-Edge SensorsJournal of Low Temperature Physics, 2012
- Small Pitch Transition-Edge Sensors with Broadband High Spectral Resolution for Solar PhysicsJournal of Low Temperature Physics, 2012
- The Extreme Physics Explorer and large area micro-channel plate optics2011
- Non-linear effects in transition edge sensors for X-ray detectionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- Characterization and reduction of unexplained noise in superconducting transition-edge sensorsApplied Physics Letters, 2004
- Optimal fitting of non-linear detector pulses with nonstationary noiseAIP Conference Proceedings, 2002
- Superconducting transition-edge-microcalorimeter X-ray spectrometer with 2eV energy resolution at 1.5keVNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000
- and x-ray emission lines of the transition metalsPhysical Review A, 1997
- Diagram and Nondiagram Lines in K Spectra of Aluminum and Oxygen from Metallic and Anodized AluminumJournal of Applied Physics, 1965
- A Note on the Al K 3 4Lines in Metal and OxideProceedings of the Physical Society. Section A, 1955