Dual-energy computed tomography has limited sensitivity for non-tophaceous gout: a comparison study with tophaceous gout
Authors:
Open Access
- 18 February 2016
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-9
Abstract
Dual-energy computed tomography (DECT) is a new diagnostic tool for gout, but its sensitivity has not been established. Our goal was to assess the sensitivity of DECT for the detection of monosodium urate (MSU) deposits in non-tophaceous and tophaceous gout, both at the level of the patient and that of the individual joint or lesion. DECT was performed on 11 patients with crystal-proven non-tophaceous gout and 10 with tophaceous gout and included both the upper and lower extremities in 20/21 patients. DECT images were simultaneously acquired at 80 and 140 kV and then processed on a workstation with proprietary software using a two-material decomposition algorithm. MSU deposits were color coded as green by the software and fused onto grey-scale CT images. The number and location of these deposits was tallied independently by two DECT-trained radiologists blinded to the clinical characteristics of the patient. Sensitivity of DECT was defined as the proportion of patients with a confirmed diagnosis of gout which was correctly identified as such by the imaging technique. All patients provided informed consent to participate in this IRB-approved study. MSU deposits were detected by DECT in ≥1 joint area in 7/11 (64 %) patients with non-tophaceous gout, but were only detected in 3/12 (25 %) joints proven by aspiration to be affected with gout. Inclusion of the upper extremity joints in the scanning protocol did not improve sensitivity. All 10 patients with tophaceous gout had MSU deposits evident by DECT. The sensitivity of DECT for individual gouty erosions was assessed in 3 patients with extensive foot involvement. MSU deposits were detected by DECT within or immediately adjacent to 13/26 (50 %) erosions. A DECT protocol that includes all lower extremity joints has moderate sensitivity in non-tophaceous and high sensitivity in tophaceous gout. However, DECT has lower sensitivity when restricted to individual crystal-proven gouty joints in non-tophaceous disease or individual erosive lesions in tophaceous gout. The detection of MSU deposits by DECT relates to their size and density and the detection parameters of the DECT scanner and adjustment of the latter might improve sensitivity.Keywords
Funding Information
- Siemens Healthcare
- National Institute of Dental and Craniofacial Research (RO1 DE12354-15A1)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32 AR48522)
- Elizabeth Hogue
This publication has 24 references indexed in Scilit:
- Imaging Appearances in GoutArthritis, 2013
- False-Negative Dual-Energy Computed Tomography in a Patient With Acute GoutJCR: Journal of Clinical Rheumatology, 2012
- Detection of periarticular urate deposits with dual energy CT in patients with acute gouty arthritisAnnals of the Rheumatic Diseases, 2012
- Mechanisms of joint damage in gout: evidence from cellular and imaging studiesNature Reviews Rheumatology, 2012
- Assessment of Tophus SizeJCR: Journal of Clinical Rheumatology, 2012
- Dual energy computed tomography in tophaceous goutAnnals of the Rheumatic Diseases, 2009
- Clinical Efficacy and Safety of Successful Longterm Urate Lowering with Febuxostat or Allopurinol in Subjects with GoutThe Journal of Rheumatology, 2009
- Noninvasive Differentiation of Uric Acid versus Non–Uric Acid Kidney Stones Using Dual-Energy CTAcademic Radiology, 2007
- Effect of urate‐lowering therapy on the velocity of size reduction of tophi in chronic goutArthritis Care & Research, 2002
- Preliminary criteria for the classification of the acute arthritis of primary goutArthritis & Rheumatism, 1977