Abstract
Posterior capsule opacification (PCO) is still a major long-term complication of modern cataract surgery. We evaluated the impact of sharp-edged intraocular lenses (IOLs) with different haptic designs made from the same hydrophobic acrylic material on posterior and anterior lens capsule opacification. Eye clinic of Kaunas University of Medicine, Lithuania. Prospective randomised clinical study. Seventy-four eyes of 74 patients scheduled for cataract surgery were included in a prospective randomised clinical study. Thirty-seven eyes of 37 patients received a three-piece acrylic hydrophobic (AcrySof, MA3OBA, Alcon) IOL; and thirty-seven eyes of 37 patients received a one-piece acrylic hydrophobic (AcrySof, SA3OAL, Alcon) IOL. Visual acuity, anterior capsule opacification (ACO), capsular folds, capsulorrhexis/optic overlapping and posterior capsule opacification (PCO) were evaluated. ACO was assessed subjectively. PCO values in the entire IOL optic area and in the central 3 mm optic zone were assessed using a photographic image-analysis system (EPCO2000). Follow-ups were performed postoperatively at 1 day, 6 months, 1 year and 2 years. There were no significant differences in best corrected visual acuity, grade of ACO and capsulorrhexis/optic overlapping between IOL types during the follow-up period. Patients in the one-piece acrylic hydrophobic IOL group more frequently presented with capsular folds behind the IOL optic area than those in the three-piece IOL group. In the three-piece acrylic hydrophobic IOL group, PCO values (mean (SD)) of the entire IOL optic area were significantly lower six months postoperative (three-piece: 0.002 (0.009); one-piece: 0.007 (0.017); p=0.04), one year postoperative (three-piece: 0.004 (0.016); one-piece: 0.026 (0.041); p=0.001) as well as one year postoperative in the central 3 mm optic zone (three-piece: 0.000 (0.0002); one-piece: 0.019 (0.049); p=0.001). However, two years postoperative, the PCO values of the groups did not show significant differences (entire IOL optic area: three-piece, 0.136 (0.223); one-piece, 0.154 (0.190); p=0.18; central zone: three-piece, 0.023 (0.065); one-piece: 0.020 (0.039); p=0.44). The 2 year follow-up after cataract surgery showed no significant difference in ACO and PCO development between three-piece and one-piece acrylic hydrophobic intraocular lenses.Keywords
This publication has 32 references indexed in Scilit:
- Comparison of posterior capsule opacification between the 1-piece and 3-piece Acrysof intraocular lenses: Two-year results of a randomized trialOphthalmology, 2004
- A prospective, randomised comparison of single and three piece acrylic foldable intraocular lensesBritish Journal of Ophthalmology, 2004
- Effect of 1-piece and 3-piece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgeryJournal of Cataract & Refractive Surgery, 2004
- Migration of lens epithelial cells through haptic root of single-piece acrylic-foldable intraocular lensAmerican Journal of Ophthalmology, 2004
- A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lensesAmerican Journal of Ophthalmology, 2003
- Selective and specific targeting of lens epithelial cells during cataract surgery using sealed- capsule irrigationJournal of Cataract & Refractive Surgery, 2003
- Pharmacologic prevention of posterior capsule opacification: In vitro effects of preservative-free lidocaine 1% on lens epithelial cellsJournal of Cataract & Refractive Surgery, 2003
- Relationship between intraocular lens biomaterials and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1998
- Photographic image analysis system of posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1997
- Posterior capsule opacificationSurvey of Ophthalmology, 1992