Comparison of analytical approaches for liquid chromatography/mass spectrometry determination of the alcohol biomarker ethyl glucuronide in urine
- 19 May 2010
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 24 (12) , 1737-1743
Abstract
Official guidelines originating from a European Union directive regulate requirements for analytical methods used to identify chemical compounds in biological matrices. This study compared different liquid chromatography/electropray ionization mass spectrometry (LC/ESI‐MS) and tandem mass spectrometry (LC/ESI‐MS/MS) procedures for accurate determination of the conjugated ethanol metabolite and alcohol biomarker ethyl glucuronide (EtG) in urine, and the value of combined EtG and ethyl sulfate (EtS) measurement. Analysis was carried out on 482 urines following solid‐phase extraction (SPE) sample cleanup or using direct injection of a diluted sample. SPE combined with LC/MS/MS was demonstrated to be the most selective and sensitive method and was chosen as reference method. The EtG results by different methods showed good correlation (r = 0.96–0.98). When comparing five reporting limits for EtG in the range 0.10–1.00 mg/L, the overall agreement with the reference method (frequency of true positives plus true negatives) was 82–97% for direct‐injection LC/MS/MS, 90–97% for SPE‐LC/MS, 86–98% for direct‐injection LC/MS, and 86–98% for direct‐injection LC/MS analysis of EtG and EtS. Most deviations were attributable to uncertainty in quantitation, when the value was close to a cutoff but the respective results were slightly above and below, or vice versa, the critical limit. However, for direct‐injection LC/MS/MS, despite earning 4 identification points, equally many negative results were due to a product ion ratio outside the ±20% deviation accepted by the guidelines. These results indicate that the likelihood of different analytical methods to provide reliable analytical results depends on the reporting limit applied. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 42 references indexed in Scilit:
- Urine tested positive for ethyl glucuronide after trace amounts of ethanolAddiction, 2009
- False‐positive liquid chromatography/tandem mass spectrometric confirmation of sebuthylazine residues using the identification points system according to EU directive 2002/657/EC due to a biogenic insecticide in tarragonRapid Communications in Mass Spectrometry, 2009
- Are liquid chromatography/electrospray tandem quadrupole fragmentation ratios unequivocal confirmation criteria?Rapid Communications in Mass Spectrometry, 2009
- Microwave assisted extraction for the determination of ethyl glucuronide in urine by gas chromatography‐mass spectrometryJournal of Applied Toxicology, 2008
- Evaluation of a new immunoassay for urinary ethyl glucuronide testingAlcohol and Alcoholism, 2007
- Validation of direct injection electrospray LC‐MS/MS for confirmation of opiates in urine drug testingJournal of Mass Spectrometry, 2007
- Does a stable isotopically labeled internal standard always correct analyte response?Journal of Pharmaceutical and Biomedical Analysis, 2007
- Laboratory guidelines and standards in clinical and forensic toxicologyAccreditation and Quality Assurance, 2006
- Confirmatory analysis for drugs of abuse in plasma and urine by high-performance liquid chromatography–tandem mass spectrometry with respect to criteria for compound identificationJournal of Chromatography B, 2004
- Criteria for the identification of compounds by liquid chromatography–mass spectrometry and liquid chromatography–multiple mass spectrometry in forensic toxicology and doping analysisAnalytica Chimica Acta, 2003