Prevention of Positional Brachial Plexopathy During Surgical Correction of Scoliosis
Authors:
- Denis S. DrummondDDDenis S. Drummond
- Miah HahnMHMiah Hahn
- Malcolm L. EckerMEMalcolm L. Ecker
- John P. DormansJDJohn P. Dormans
- 1 April 2000
- journal article
- case report
- Published by Wolters Kluwer Health in Journal of Spinal Disorders
- Vol. 13 (2) , 178-182
Abstract
Continuous intraoperative monitoring of spinal cord function using somatosensory evoked potentials (SSEP) has gained nearly universal acceptance as a reliable and sensitive method for detecting and possibly preventing neurologic injury during surgical correction of spinal deformities. In several reports, spinal cord injury was identified successfully based on changes in SSEP response characteristics, specifically amplitude and latency. Less well documented and used, however, is monitoring of peripheral nerve function with SSEPs to identify and prevent the neurologic sequelae of prolonged prone positioning on a spinal frame. The authors describe a patient who underwent surgical removal of spinal instrumentation but was not monitored. A brachial plexopathy developed in this patient from pressure on the axilla exerted by a Relton-Hall positioning frame during spinal surgery. In addition, data are presented from 15 of 500 consecutive pediatric patients who underwent surgical correction of scoliosis between 1993 and 1997 with whom intermittent monitoring of ulnar nerve SSEPs was used successfully to identify impending brachial plexopathy, a complication of prone positioning. A statistically significant reduction in ulnar nerve SSEP amplitude was observed in 18 limbs of the 500 patients (3.6%) reviewed. Repositioning the arm(s) or shoulders resulted in nearly immediate improvement of SSEP amplitude, and all awoke without signs of brachial plexopathy. This complication can be avoided by monitoring SSEPs to ulnar nerve stimulation for patients placed in the prone position during spinal surgery.Keywords
This publication has 12 references indexed in Scilit:
- Somatosensory evoked potentials are not a sensitive indicator of potential positioning injury in the prone patientJournal of Clinical Monitoring and Computing, 1996
- Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter surveyElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1995
- Neurophysiologic Detection of a Unilateral Motor Deficit Occurring During the Noncritical Phase of Scoliosis SurgerySpine, 1994
- An unusual cause of postoperative brachial plexus palsyBritish Journal of Anaesthesia, 1994
- Intraoperative Somatosensory Evoked Potential Monitoring Predicts Peripheral Nerve Injury during Cardiac SurgeryAnesthesiology, 1993
- Nerve Injury Associated with AnesthesiaAnesthesiology, 1990
- The use of somatosensory evoked potentials for detection of neuropraxia during shoulder arthroscopyArthroscopy, 1988
- INTRA‐OPERATIVE SPINAL CORD MONITORING DURING SURGERY FOR SCOLIOSIS USING SOMATOSENSORY EVOKED POTENTIALSAnz Journal of Surgery, 1984
- Detection of Brachial Plexus Dysfunction by Somatosensory Evoked Potential Monitoring—A Report of Two CasesAnesthesiology, 1984
- Transoral Microsurgical Odontoid Resection and Spinal Cord MonitoringSpine, 1979