Phospholipid polymer surfaces reduce bacteria and leukocyte adhesion under dynamic flow conditions
- 30 March 2005
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 73A (3) , 359-366
Abstract
Persistence of infection can occur when the host immune response is compromised because of the presence of a foreign implant. Surface modification of biomaterials with phospholipid polymers may enhance biocompatibility and reduce incidence of infection by impeding bacterial and leukocyte adhesion. A rotating disk model, which generates shear stress from 0 to 18 dynes/cm2, was used to characterize adhesion of neutrophils, monocytes, and bacteria in phosphate‐buffered saline (PBS) or 25% human serum on polyethylene terephthalate surfaces coated with a phospholipid polymer, poly[ω‐methacryloyloxyalkyl phosphorylcholine (MAPC)‐co‐n‐butyl methacrylate (BMA)]. The material designated PMB30 contains a methylene chain length, (CH2)n, of n = 2, whereas PMHB30 contains a chain length of n = 6. In PBS, bacterial adhesion was shear stress dependent with the lowest bacterial density observed on PMB30. However, the presence of serum proteins eliminated shear stress and surface chemistry effects in addition to bacterial adhesion reduced to <10% of adhesion in PBS. Trends for leukocyte adhesion in serum demonstrated shear dependence with PMB30 exhibiting the lowest cell density throughout the range of shear stresses. In conclusion, modification of the polyethylene terephthalate surfaces with phospholipid polymers resulted in reduced bacterial and leukocyte adhesion. Furthermore, shortening the methylene chain length of the MAPC copolymer most effectively reduced adhesion. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res 73A: 359–366, 2005Keywords
This publication has 39 references indexed in Scilit:
- Adhesion of human U937 macrophages to phosphorylcholine‐coated surfacesJournal of Biomedical Materials Research Part A, 2004
- Pathogenesis of infections due to coagulasenegative staphylococciThe Lancet Infectious Diseases, 2002
- Shear stress and material surface effects on adherent human monocyte apoptosisJournal of Biomedical Materials Research, 2002
- Shear stress effects on bacterial adhesion, leukocyte adhesion, and leukocyte oxidative capacity on a polyetherurethaneJournal of Biomedical Materials Research, 1999
- Leukocyte?biomaterial interactions in the presence ofStaphylococcus epidermidis: Flow cytometric evaluation of leukocyte activation (Student Research Award in the Hospital Intern, Resident, or Clinical Fellow Category, 23rd Annual Meeting of the Society for Biomaterials, New Orleans, LA, April 30-May 4, 1997)Journal of Biomedical Materials Research, 1997
- MICROBIAL BIOFILMSAnnual Review of Microbiology, 1995
- Staphylococcus epidermidisAdhesion to Hydrophobic Biomedical Polymer Is Mediated by PlateletsThe Journal of Infectious Diseases, 1993
- Preparation of Phospholipid Polylners and Their Properties as Polymer Hydrogel MembranesPolymer Journal, 1990
- Adhesive colonization of biomaterials and antibiotic resistanceBiomaterials, 1987
- EFFECT OF EXTRACELLULAR SLIME SUBSTANCE FROM STAPHYLOCOCCUS EPIDERMIDIS ON THE HUMAN CELLULAR IMMUNE RESPONSEThe Lancet, 1984