Fracture Strength of Yttria‐Stabilized Zirconium‐Dioxide (Y‐TZP) Fixed Dental Prostheses (FDPs) with Different Abutment Core Thicknesses and Connector Dimensions
- 4 January 2013
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 22 (5) , 377-382
Abstract
Purpose: The aim of this study was to investigate the fracture strength and fracture mode of yttria‐stabilized tetragonal zirconia polycrystal (Y‐TZP) posterior three‐unit FDPs with varying connector dimension and abutment core thickness.Materials and Methods: Seventy 3‐unit posterior FDP cores made of Y‐TZP were divided into 7 groups with varying connector dimensions and abutment core thicknesses. All the FDPs underwent a simulated aging process including veneering, firing applications, thermocycling, and cyclic preloading. Finally the FDPs were subjected to load until fracture.Results: Significant difference was seen between the different subgroups (p < 0.05). Groups with the same connector dimension showed no significant difference in fracture strength. All fractures of the specimens involved the connector.Conclusions: Within the limitations of this in vitro study, it can be concluded that the strength of an all‐ceramic Y‐TZP FDP beam depends more on the connector dimension than on the thickness of the abutment core. Results indicate that the minimum abutment core thickness of an all‐ceramic Y‐TZP FDP might be reduced, compared to the recommended thickness, without reducing the strength of the reconstruction. This indication, however, needs to be verified by further studies before being considered generally applicable.Keywords
This publication has 31 references indexed in Scilit:
- Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal–ceramic fixed dental prosthesesDental Materials, 2012
- Complete and partial contour zirconia designs for crowns and fixed dental prostheses: A clinical reportThe Journal of Prosthetic Dentistry, 2011
- The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental prosthesesActa Odontologica Scandinavica, 2011
- Performance of Dental Ceramics: Challenges for ImprovementsJournal of Dental Research, 2011
- An overview of zirconia ceramics: Basic properties and clinical applicationsJournal of Dentistry, 2007
- Strength and reliability of four-unit all-ceramic posterior bridgesDental Materials, 2005
- Fate of vital pulps beneath a metal‐ceramic crown or a bridge retainerInternational Endodontic Journal, 2005
- All‐ceramic fixed partial dentures designed according to the DC‐Zirkon® technique. A 2‐year clinical studyJournal of Oral Rehabilitation, 2005
- Fracture toughness and mechanical strength of Y-TZP/PSZ ceramicsScripta Materialia, 2001
- Biomechanical aspects of fixed bridgework supported by natural teeth and endosseous implantsPeriodontology 2000, 1994