Methodology for the Determination of Stoichiometry and Metal Impurities in New PZT Ceramics by Inductively Coupled Plasma Optical Spectrometry (ICP OES)
- 19 February 2011
- journal article
- research article
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 44 (2) , 138-145
Abstract
An inductively coupled plasma optical emission spectrometry (ICP OES) method for Pb, Zr, Ti, Sr, Cr, Fe, Cu, Mn, and Al determination in PZT-ceramics is described. Careful analytical work was carried out in order to evaluate precision, accuracy, and matrix interference. Different procedures were investigated for the ceramics decomposition. Axially viewed plasma operating conditions were evaluated for trace elements (Al, Fe, Cu, Mn, and Cr) in presence of sample matrix. The relative standard deviation (RSD) ranged from 0.7 to 3.9%, whereas the analytes recoveries in the spiked samples ranged from 92 to 119%. The detection limits (LODs) of trace elements ranged from 2.4 to 2.6 µg g−1. The developed method is useful for evaluating the PZT-ceramics synthesis.Keywords
This publication has 13 references indexed in Scilit:
- Matrix effect of aluminium, calcium and magnesium in axially viewing inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 2007
- Determination of major, minor and trace elements in cobalt-substituted lithium nickelate ceramic powders by inductively coupled plasma optical emission spectrometryAnalytical and Bioanalytical Chemistry, 2006
- Stoichiometry determination of (Pb,La)(Zr,Ti)O3-type nano-crystalline ferroelectric ceramics by wavelength-dispersive X-ray fluorescence spectrometryAnalytical and Bioanalytical Chemistry, 2006
- Substituição do Pb2+ por La3+ na rede cristalina do sistema ferroelétrico PZT (53/47): influência nas propriedades estruturais, microestruturais e elétricasCerâmica, 2005
- Elemental matrix effects in ICP-AESJournal of Analytical Atomic Spectrometry, 2002
- Trace element analysis of superconductor oxides by ICP-AESJournal of Analytical Atomic Spectrometry, 2000
- Microwave-assisted Acid Dissolution of Sintered Advanced Ceramics for Inductively Coupled Plasma Atomic Emission SpectrometryJournal of Analytical Atomic Spectrometry, 1997
- Empirical procedure for the reduction of mixed-matrix effects in inductively coupled plasma atomic emission spectrometry using an internal standard and proportional correctionAnalytical and Bioanalytical Chemistry, 1996
- Determination of macro-constituents in advanced ceramic materials by inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1992
- Determination of impurities in lead zirconate–titanate electroceramics by inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1992