Design and utilisation of protocols to characterise dynamic PET uptake of two tracers using basis pursuit
- 22 May 2017
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (12) , 4897-4916
Abstract
Imaging using more than one biological process using PET could be of great utility, but despite previously proposed approaches to dual-tracer imaging, it is seldom performed. The alternative of performing multiple scans is often infeasible for clinical practice or even in research studies. Dual-tracer PET scanning allows for multiple PET radiotracers to be imaged within the same imaging session. In this paper we describe our approach to utilise the basis pursuit method to aid in the design of dual-tracer PET imaging experiments, and later in separation of the signals. The advantage of this approach is that it does not require a compartment model architecture to be specified or even that both signals are distinguishable in all cases. This means the method for separating dual-tracer signals can be used for many feasible and useful combinations of biology or radiotracer, once an appropriate scanning protocol has been decided upon. Following a demonstration in separating the signals from two consecutively injected radionuclides in a controlled experiment, phantom and list-mode mouse experiments demonstrated the ability to test the feasibility of dual-tracer imaging protocols for multiple injection delays. Increases in variances predicted for kinetic macro-parameters V D and K I in brain and tumoral tissue were obtained when separating the synthetically combined data. These experiments confirmed previous work using other approaches that injections delays of 10–20 min ensured increases in variance were kept minimal for the test tracers used. On this basis, an actual dual-tracer experiment using a 20 min delay was performed using these radio tracers, with the kinetic parameters ( V D and K I ) extracted for each tracer in agreement with the literature. This study supports previous work that dual-tracer PET imaging can be accomplished provided certain constraints are adhered to. The utilisation of basis pursuit techniques, with its removed need to specify a model architecture, allows the feasibility of a range of imaging protocols to be investigated via simulation in a straight-forward manner for a wide range of possible scenarios. The hope is that the ease of utilising this approach during feasibility studies and in practice removes any perceived technical barrier to performing dual-tracer imaging.Keywords
Funding Information
- National Health and Medical Research Council of Australia (631567)
- Cancer Council Queensland (R14/2173)
- Cure Brain Cancer Foundation (R14/2173)
This publication has 29 references indexed in Scilit:
- Kinetic Modeling and Graphical Analysis of 18F-Fluoromethylcholine (FCho), 18F-Fluoroethyltyrosine (FET) and 18F-Fluorodeoxyglucose (FDG) PET for the Fiscrimination between High-Grade Glioma and Radiation Necrosis in RatsPLOS ONE, 2016
- Increasing feasibility and utility of 18 F-FDOPA PET for the management of gliomaNuclear Medicine and Biology, 2015
- Hypoxia Imaging in Gliomas With 18F-Fluoromisonidazole PET: Toward Clinical TranslationSeminars in Nuclear Medicine, 2015
- Direct Parametric Image Reconstruction of Rapid Multi-tracer PETLecture Notes in Computer Science, 2013
- Quantification of Brain Glucose Metabolism by 18F-FDG PET with Real-Time Arterial and Image-Derived Input Function in MiceJournal of Nuclear Medicine, 2012
- Dual-isotope PET using positron-gamma emittersPhysics in Medicine & Biology, 2011
- Simultaneous Dual-tracer PET Imaging of the Rat Brain and its Application in the Study of Cerebral IschemiaMolecular Imaging and Biology, 2010
- Dynamic Dual-Tracer PET Reconstruction2009
- Positron Emission Tomography Compartmental ModelsJournal of Cerebral Blood Flow & Metabolism, 2001
- Noise properties of the EM algorithm. I. TheoryPhysics in Medicine & Biology, 1994