Continuous optical detection of small-molecule analytes in complex biomatrices
Preprint
Abstract
Current technology for measuring specific biomarkers – continuously in complex samples, without sample preparation – is limited to just handful of molecules such as glucose and blood oxygen. In this work, we present the first optical biosensor system that enables continuous detection of a wide range of biomarkers in complex samples, such as human plasma. Our system employs a modular duplex-bubble switch (DBS) architecture that converts aptamers into structure-switching fluorescence probes whose affinity and kinetics can be readily tuned. These DBS constructs are coupled to a fiber-optic detector that measures the fluorescence change only within an evanescent field, thereby minimizing the impact of background autofluorescence and enabling direct detection of analytes at physiologically relevant concentrations even in interferent-rich sample matrices. Using our system, we achieved continuous detection of dopamine in artificial cerebrospinal fluid for >24 hours with sub-second resolution and a limit of detection (LOD) of 1 µM. We subsequently demonstrated the system’s generalizability by configuring it to detect cortisol with nanomolar sensitivity in undiluted human plasma. Both sensors achieved LODs orders of magnitude lower than the K D of the DBS element, highlighting the potential to achieve sensitive detection even when using aptamers with modest affinity.Keywords
This publication has 33 references indexed in Scilit:
- Real-Time, Aptamer-Based Tracking of Circulating Therapeutic Agents in Living AnimalsScience Translational Medicine, 2013
- Solution-Phase vs Surface-Phase Aptamer-Protein Affinity from a Label-Free Kinetic BiosensorPLOS ONE, 2013
- Capture-SELEX: Selection of DNA Aptamers for Aminoglycoside AntibioticsJournal of Analytical Methods in Chemistry, 2012
- Tapered Optical Fiber Sensor for Label-Free Detection of BiomoleculesSensors, 2011
- Switch-based biosensors: a new approach towards real-time, in vivo molecular detectionTrends in Biotechnology, 2011
- Determination of Glucose Levels Using a Functionalized Hydrogel−Optical Fiber Biosensor: Toward Continuous Monitoring of Blood Glucose in VivoAnalytical Chemistry, 2009
- Continuous, Real-Time Monitoring of Cocaine in Undiluted Blood Serum via a Microfluidic, Electrochemical Aptamer-Based SensorJournal of the American Chemical Society, 2009
- Optimization of Electrochemical Aptamer-Based Sensors via Optimization of Probe Packing Density and Surface ChemistryLangmuir, 2008
- Plasma free cortisol fraction reflects levels of functioning corticosteroid-binding globulinClinica Chimica Acta, 2005
- Detection of physiological concentrations of cortisol and cortisone in human hairClinical Biochemistry, 2004