Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber
Open Access
- 1 June 2018
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (06) , P06022
Abstract
The 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of 155 ± 28 cm.Keywords
All Related Versions
This publication has 8 references indexed in Scilit:
- Index of refraction, Rayleigh scattering length, and Sellmeier coefficients in solid and liquid argon and xenonNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2017
- Scintillation light from cosmic-ray muons in liquid argonJournal of Instrumentation, 2016
- Performance and Results of the LBNE 35 Ton Membrane Cryostat PrototypePhysics Procedia, 2015
- The Liquid Argon Purity DemonstratorJournal of Instrumentation, 2014
- The NOvA Timing System: A system for synchronizing a long baseline neutrino experimentJournal of Physics: Conference Series, 2012
- Fluorescence efficiency and visible re-emission spectrum of tetraphenyl butadiene films at extreme ultraviolet wavelengthsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- The scintillation of liquid argonEurophysics Letters, 2010
- GAIN AND THRESHOLD CONTROL OF SCINTILLATION COUNTERS IN THE CDF MUON UPGRADE FOR RUN IIInternational Journal of Modern Physics A, 2001