Retrograde Drilling of Talar Osteochondritis Dissecans Lesions: A Feasibility and Accuracy Analysis of a Novel Electromagnetic Navigation Method Versus a Standard Fluoroscopic Method
- 11 June 2012
- journal article
- research article
- Published by Wiley in Arthroscopy
- Vol. 28 (10) , 1547-1554
Abstract
Purpose: A novel method using an electromagnetic navigation system (ENS) was developed, and its feasibility and accuracy for retrograde drilling procedures were evaluated and compared with the standard freehand fluoroscopic method in an experimental setting. Methods: A controlled laboratory study of 16 standard freehand fluoroscopically guided and 16 electromagnetically navigated retrograde drilling procedures was performed on 4 cadaveric human ankle joints. Four artificial cartilage lesions were consecutively set, 2 on the medial and 2 on the lateral talar dome. Drilling accuracy was measured in terms of the distance from the final position of the drill bit to the tip of the probe hook and the distance between the tip of the drill bit and the center of the cartilage lesion on the articular cartilage surface. Intraoperative fluoroscopy exposure times were documented, as were readjustments of drilling directions or complete restarts. All procedures were timed with a stopwatch. Results: Successful retrograde drilling was accomplished in 12 cases with the standard fluoroscopy‐guided technique and in all 16 ENS‐guided procedures. The overall mean time for the fluoroscopy‐guided procedures was 660.00 ± 239.87 seconds and the overall mean time for the ENS method was 308.06 ± 54.03 seconds, providing a mean time benefit of 420.13 seconds. The mean distance from the final position of the drill bit to the tip of the probe hook was 3.25 ± 1.29 mm for the standard method and 2.19 ± 0.54 mm for the ENS method, and the mean distance between the tip of the drill bit and the center of the cartilage lesion on the articular cartilage surface was 2.50 ± 0.97 mm for the standard method and 0.88 ± 0.81 mm for the ENS method. Conclusions: Compared with the standard fluoroscopic technique, the ENS method used in this study showed higher accuracy and a shorter procedure time and required no X‐ray radiation. Clinical Relevance: The novel method considerably improves on the standard operating procedure in terms of safety, operation time, and radiation exposure.Keywords
This publication has 17 references indexed in Scilit:
- Analysis of radiation exposure to the orthopaedic trauma patient during their inpatient hospitalisationInjury, 2012
- Minimal-invasive retrograde Anbohrung der Osteochondrosis dissecans des Femurkondylus mit einem speziellen ZielinstrumentariumOperative Orthopädie und Traumatologie, 2011
- MRI-guided percutaneous retrograde drilling of osteochondritis dissecans of the kneeSkeletal Radiology, 2011
- Fluoro‐Free navigated retrograde drilling of osteochondral lesionsKnee Surgery, Sports Traumatology, Arthroscopy, 2010
- Osteochondral lesions of the talus: Current conceptOrthopaedics & Traumatology: Surgery & Research, 2010
- Treatment of osteochondral lesions of the talus: a systematic reviewKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- Current Concepts in the Diagnosis and Treatment of Osteochondral Lesions of the AnkleThe American Journal of Sports Medicine, 2009
- Initial Outcomes of 3-Dimensional Imaging-Based Computer-Assisted Retrograde Drilling of Talar Osteochondral LesionsThe American Journal of Sports Medicine, 2009
- Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesionsThe Journal of Bone and Joint Surgery. British volume, 2007
- The anterior approach for the treatment of posterior osteochondral lesions of the talus: comparison of different surgical techniquesArchives of orthopaedic and trauma surgery, 2005