Digital assessment of walking ability: Validity and reliability of the automated figure-of-eight walk test in older adults
Open Access
- 10 February 2025
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (2) , e0316612
Abstract
Background: The Figure-of-Eight Walk Test (F8WT) can assess straight- and curved-path walking ability, but the validity and reliability of automated measurement of the F8WT using digital device has not yet been studied. The aim of this study was to verify the validity (method comparison) and test-retest reliability of the automated FW8T (aFW8T) using a digital device based on image analysis by comparing the results of the aF8WT with those of the manual F8WT (mF8WT). Methods: Community-dwelling older adults underwent the mF8WT performed by a physiotherapist and the aF8WT using the Digital Senior Fitness Test system. To verify the test-retest reliability, the aF8WT was administered again to a randomly selected group of participants one week after the baseline test. The intraclass correlation coefficient (ICC) and Pearson’s correlation analysis were used to verify the degree of agreement between the results of and correlation between the mF8WT and aF8WT, respectively. The 95% confidence interval (CI) of the limits of agreement (LoA) was obtained using Bland–Altman analysis. Results: The analysis included 83 participants (mean age 71.6 ± 4.7 years). The participants’ mF8WT and aF8WT results were 29.1 ± 4.9 and 29.8 ± 4.9 seconds, respectively. Pearson’s correlation analysis showed a very strong correlation between the mF8WT and aF8WT results with r = 0.91 (p < 0.001), and the ICC between the mF8WT and aF8WT results was 0.95 (0.91–0.97), showing excellent agreement. The 95% CI of the LoA was ˗0.7 (˗4.8 to 3.3) seconds in the Bland–Altman analysis. In an analysis of the test-retest reliability of the aF8WT, participants’ aF8WT results were 30.9 ± 4.7 seconds (baseline) and 29.6 ± 4.9 seconds (retest), with an ICC of 0.94 (0.81–0.98, p < 0.001), indicating excellent reliability. Conclusion: Automated measurement of the F8WT using a digital device showed excellent validity and reliability. The aF8WT can be used to assess and monitor the walking ability of community-dwelling older adults.Keywords
Funding Information
- Ministry of Trade, Industry and Energy (20014701)
This publication has 34 references indexed in Scilit:
- Accuracy of the figure of 8 walk test with and without dual-task to predict falls in older adultsJournal of Bodywork and Movement Therapies, 2022
- Extraction of gait parameters from marker-free video recordings of Timed Up-and-Go tests: Validity, inter- and intra-rater reliabilityGait & Posture, 2021
- The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?Physiotherapy, 2019
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Using Timed Up and Go and Usual Gait Speed to Predict Incident Disability in Daily Activities Among Community-Dwelling Adults Aged 65 and OlderArchives of Physical Medicine and Rehabilitation, 2014
- Investigating the predictive ability of gait speed and quadriceps strength for incident falls in community-dwelling older women at high risk of fractureArchives of Gerontology and Geriatrics, 2014
- Contributions of Cognitive Function to Straight- and Curved-Path Walking in Older AdultsArchives of Physical Medicine and Rehabilitation, 2012
- Normative spatiotemporal gait parameters in older adultsGait & Posture, 2011
- Walking is more like catching than tapping: gait in the elderly as a complex cognitive taskExperimental Brain Research, 2005
- The special nature of human walking and its neural controlTrends in Neurosciences, 2002