Multiplex tumor marker detection with new chemiluminescent immunoassay based on silica colloidal crystal beads
Authors:
- 13 November 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (1) , 177-181
Abstract
A new multiplex chemiluminescent immunoassay (CLIA) based on silica colloidal crystal beads (SCCBs) was developed for tumor marker detection. As the code is the characteristic reflection peak originating from the stop-band of colloid crystal, they avoid photobleaching, the potential interference of encoding fluorescence with analyte-detection fluorescence and chemical instability. Meanwhile our SCCBs suspension array improved the luminescence analysis efficiency by using chemiluminescent detection of enzyme labels. By forming a sandwich immunocomplex on SCCBs, the proposed suspension array was used for simultaneous multiplex detection of tumor markers in one test tube. The results showed that the linear range was 0.5–100ng ml−1 and 1.0–120ng ml−1 for carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) with a detection limit of 0.12ng ml−1 and 0.16ng ml−1 at 3σ. The proposed array showed the storage stability and the accuracy for sample detection were acceptable, and the results were in acceptable agreement with the reference electrochemiluminescence method. This technique provided an automated, simple, sensitive and low-cost approach for multianalyte immunoassay.Keywords
This publication has 28 references indexed in Scilit:
- Automated Support-Resolution Strategy for a One-Way Chemiluminescent Multiplex ImmunoassayAnalytical Chemistry, 2009
- Multiplex detection of tumor markers with photonic suspension arrayAnalytica Chimica Acta, 2009
- Polymer‐Based Elemental Tags for Sensitive BioassaysAngewandte Chemie International Edition, 2007
- Magnetic Core−Shell Fe3O4@Ag Nanoparticles Coated Carbon Paste Interface for Studies of Carcinoembryonic Antigen in Clinical ImmunoassayThe Journal of Physical Chemistry B, 2006
- Macro-molecular chemiluminescent complex for enhanced immuno-detection onto microtiter plate and protein biochipSensors and Actuators B: Chemical, 2006
- Serum alpha-fetoprotein levels in patients with advanced hepatitis C: Results from the HALT-C TrialJournal of Hepatology, 2005
- Multiplex bead array assays for detection of soluble cytokines: Comparisons of sensitivity and quantitative values among kits from multiple manufacturersCytometry Part B: Clinical Cytometry, 2004
- A Core−Shell-Type Fluorescent Nanosphere Possessing Reactive Poly(ethylene glycol) Tethered Chains on the Surface for Zeptomole Detection of Protein in Time-Resolved Fluorometric ImmunoassayAnalytical Chemistry, 2003
- Lophine derivatives and analogues as new phenolic enhancers for the luminol–hydrogen peroxide–horseradish peroxidase chemiluminescence systemAnalytica Chimica Acta, 2000
- Highly Sensitive Electrochemiluminescence Immunoassay Using the Ruthenium Chelate-Labeled Antibody Bound on the Magnetic Micro BeadsAnalytical Sciences, 1999