Polyethylene Exchange Only for Prosthetic Knee Instability
Authors:
- Thomas K. FehringTFThomas K. Fehring
- William L. GriffinWGWilliam L. Griffin
- J. Bohannon MasonJMJ. Bohannon Mason
- Thomas H. McCoyTMThomas H. McCoy
- 1 December 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 405 (405) , 182-188
Abstract
From 1987 to 1996, 47 revision total knee arthroplasties were done for tibiofemoral instability. Sixteen of these patients had polyethylene exchange only to treat their instability. Fourteen of these patients were available for review. The mean followup was 56 months. The mean Hospital for Special Surgery Knee Score increased from 50 points preoperatively to 73 points at the most recent followup. Clinically, stable knees were produced in 71% of patients (10 of 14). The results of the current study suggest that polyethylene exchange can be an effective, low morbidity procedure to treat certain types of prosthetic knee instability. A failure rate of 29% (four of 14) however, is concerning. Alternative methods of stabilization should be used, if there is any question concerning the stability of a construct where a polyethylene exchange only is used.Keywords
This publication has 4 references indexed in Scilit:
- Knee Instability After Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1994
- Results of Revision Total Knee Arthroplasty Performed for Aseptic LooseningClinical Orthopaedics and Related Research, 1990
- The Results of Revision Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1988
- Duo-Condylar Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1973