Repeat left ventricular assist device exchange with inflow or outflow correction for recurrent pump thrombosis and cerebral haemorrhage through limited incisions†
- 27 March 2018
- journal article
- editorial
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 54 (4) , 781-783
Abstract
Left ventricular assist devices (LVADs) may require subsequent pump exchange due to device thrombosis or thromboembolism. A limited left thoracotomy may offer advantages over standard full sternotomy in redo procedures by preserving pristine median access and decreasing the potential for re-entry injuries, postoperative bleeding and transfusion requirements. We describe repeat LVAD exchange via the left limited thoracotomy with outflow graft anastomosis to the left subclavian artery with the correction of LVAD inflow cannula angulation following recurrent LVAD thromboses.Keywords
This publication has 3 references indexed in Scilit:
- Exchange of a HeartWare HVAD to a HeartMate 3 left ventricular assist deviceThe Journal of Heart and Lung Transplantation, 2017
- Impact of long term left ventricular assist device therapy on donor allocation in cardiac transplantationThe Journal of Heart and Lung Transplantation, 2013
- HeartWare Left Ventricular Assist Device Implantation Through Bilateral Anterior ThoracotomyThe Annals of Thoracic Surgery, 2012