Toward the development of a specific non-enzymatic amperometric sensor for determining uric acid in fermentation samples
Authors:
Open Access
- 12 February 2025
- journal article
- research article
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (3) , 1-12
Abstract
This paper proposes the development of a specific non-enzymatic amperometric sensor based on electrodeposited copper nanoparticles (Cu-NPs) for the determination of uric acid (UA) in fermentation samples. Through optimization of the Cu-NPs-containing sensing layer, it was demonstrated that copper(II)-induced oxidation (catalytic effect) in the presence of molecular oxygen is more effective for determining UA than the adsorption of UA on Cu and Cu-oxide surfaces. More importantly, simply changing the sensing layer’s surface chemistry by increasing the defect CuxOy on the surface of Cu-NPs after heating at 70 °C for only 20 min significantly improved the specificity of UA determination in both model and real fermentation samples (viz. supernatants of S. cerevisiae and E. coli). This study can be used as a guideline for the future assembly of functional electrodeposited sensing layers for the specific determination of target electroactive bioanalyte(s). Graphical abstractKeywords
Funding Information
- Universität des Saarlandes
This publication has 36 references indexed in Scilit:
- Mechanistic aspects of glycerol oxidation on palladium electrocatalysts in model aqueous and fermentation media solutionsElectrochimica Acta, 2024
- Towards controlled and simple design of non-enzymatic amperometric sensor for glycerol determination in yeast fermentation mediumAnalytical and Bioanalytical Chemistry, 2024
- A tandem of GC‐MS and electroanalysis for a rapid chemical profiling of bacterial extracellular matrixElectroanalysis, 2023
- Approaches to Improving the Selectivity of NanozymesAdvanced Materials, 2023
- Single-Atom Cobalt-Based Electrochemical Biomimetic Uric Acid Sensor with Wide Linear Range and Ultralow Detection LimitNano-Micro Letters, 2020
- Copper(II)‐Catalyzed Aerobic Oxidation of Amines: Divergent Reaction Pathways by Solvent Control to Imines and NitrilesAsian Journal of Organic Chemistry, 2019
- Standard addition method with cumulative spikes: uric acid determination in human serum by voltammetry with optimized uncertaintyAccreditation and Quality Assurance, 2018
- Regulation of uric acid metabolism and excretionInternational Journal of Cardiology, 2016
- Simultaneous determination of uric acid, xanthine, hypoxanthine and caffeine in human blood serum and urine samples using electrochemically reduced graphene oxide modified electrodeAnalytica Chimica Acta, 2013
- Sensitivity and Selectivity of Electrochemical Biosensors for Inhibitor Determination1998