Accurate mass measurements and ultrahigh-resolution: evaluation of different mass spectrometers for daily routine analysis of small molecules in negative electrospray ionization mode
- 8 May 2011
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (10) , 3595-3606
Abstract
Six mass spectrometers based on different mass analyzer technologies, such as time-of-flight (TOF), hybrid quadrupole-TOF (Q-TOF), orbitrap, Fourier transform ion cyclotron resonance (FT-ICR), and triple quadrupole (QqQ), installed at independent laboratories have been tested during a single day of work for the analysis of small molecules in negative electrospray ionization (ESI) mode. The uncertainty in the mass measurements obtained from each mass spectrometer has been determined by taking the precision and accuracy of replicate measurements into account. The present study is focused on calibration processes (before, after, and during the mass measurement), the resolving power of the mass spectrometers, and the data processing for obtaining elemental formulae. The mass range between m/z 100 and 600 has been evaluated with a mix of four standards. This mass range includes small molecules usually detected in food and environmental samples. Negative ESI has been tested as there is almost no data on accurate mass (AM) measurements in this mode. Moreover, it has been used because it is the ESI mode for analysis of many compounds, such as pharmaceutical, herbicides, and fluorinated compounds. Natural organic matter has been used to demonstrate the significance of ultrahigh-resolution in complex mixtures. Sub-millidalton accuracy and precision have been obtained with Q-TOF, FT-ICR, and orbitrap achieving equivalent results. Poorer accuracy and precision have been obtained with the QqQ used: 11 mDa root-mean-square error and 6–11 mDa standard deviation. Some advice and requirements for daily AM routine analysis are also discussed here.Keywords
This publication has 25 references indexed in Scilit:
- Multiple‐stage mass spectrometry analysis of bisphenol A diglycidyl ether, bisphenol F diglycidyl ether and their derivativesRapid Communications in Mass Spectrometry, 2010
- PROTEOMICS: Ten years in the fieldProteomics, 2009
- Advanced characterization of marine dissolved organic matter by combining reversed-phase liquid chromatography and FT-ICR-MSMarine Chemistry, 2008
- Seven Golden Rules for heuristic filtering of molecular formulas obtained by accurate mass spectrometryBMC Bioinformatics, 2007
- From mass to structure: an aromaticity index for high‐resolution mass data of natural organic matterRapid Communications in Mass Spectrometry, 2006
- Use of quadrupole time‐of‐flight mass spectrometry in the elucidation of unknown compounds present in environmental waterRapid Communications in Mass Spectrometry, 2004
- Exact mass measurement on an electrospray ionization time‐of‐flight mass spectrometer: error distribution and selective averagingJournal of Mass Spectrometry, 2003
- High‐sensitivity quantitation of cabergoline and pergolide using a triple‐quadrupole mass spectrometer with enhanced mass‐resolution capabilitiesJournal of Mass Spectrometry, 2003
- Accurate mass measurement at enhanced mass‐resolution on a triple quadrupole mass‐spectrometer for the identification of a reaction impurity and collisionally‐induced fragment ions of cabergolineRapid Communications in Mass Spectrometry, 2003
- The ideal mass analyzer: Fact or fiction?International Journal of Mass Spectrometry and Ion Processes, 1987