Direct measurement of the group refractive index of air with interferometry between adjacent femtosecond pulses
- 20 July 2002
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 41 (21) , 4318-4324
Abstract
The group refractive index of air in laboratory conditions is measured directly between adjacent femtosecond laser pulses by a new interferometry technique. Measurement of the repetition rate of the mode-locked pulse train that gives the maximum amplitude of the interference-signal envelope enables us to determine the group refractive index of air within a standard deviation of 2 × 10-7. This simple method without vacuum reference is attractive for measuring the group refractive index needed for precise distance measurements in open fields.Keywords
This publication has 11 references indexed in Scilit:
- High-accuracy measurement of 240-m distance in an optical tunnel by use of a compact femtosecond laserApplied Optics, 2000
- Refractive index of air 2 Group indexApplied Optics, 1999
- High-resolution distance meter using optical intensity modulation at 28 GHzMeasurement Science and Technology, 1998
- Influence of resonances on the phase and the group refractive indices of airJournal of Geodesy, 1997
- The problem of obtaining formulae for the refractive index of air for high-precision EDMJournal of Geodesy, 1997
- Group refractive index measurement by Michelson interferometerOptics Communications, 1990
- Update of the Edlén Formulae for the Refractive Index of AirMetrologia, 1988
- Bi-directional fringe counting interference refractometerPrecision Engineering, 1983
- Measurement of the group refractive index of air by two-wavelength interferometryOptics Communications, 1982
- The Refractive Index of AirMetrologia, 1966