Combustor Turbine Interface Studies—Part 1: Endwall Effectiveness Measurements
Authors:
- 1 April 2003
- journal article
- Published by Wiley in Journal of Turbomachinery
- Vol. 125 (2) , 193-202
Abstract
Improved durability of gas turbine engines is an objective for both military and commercial aeroengines as well as for power generation engines. One region susceptible to degradation in an engine is the junction between the combustor and first vane given that the main gas path temperatures at this location are the highest. The platform at this junction is quite complex in that secondary flow effects, such as the leading edge vortex, are dominant. Past computational studies have shown that the total pressure profile exiting the combustor dictates the development of the secondary flows that are formed. This study examines the effect of varying the combustor liner film-cooling and junction slot flows on the adiabatic wall temperatures measured on the platform of the first vane. The experiments were performed using large-scale models of a combustor and nozzle guide vane in a wind tunnel facility. The results show that varying the coolant injection from the upstream combustor liner leads to differing total pressure profiles entering the turbine vane passage. Endwall adiabatic effectiveness measurements indicate that the coolant does not exit the upstream combustor slot uniformly, but instead accumulates along the suction side of the vane and endwall. Increasing the liner cooling continued to reduce endwall temperatures, which was not found to be true with increasing the film-cooling from the liner.Keywords
This publication has 14 references indexed in Scilit:
- Measurements Over a Film-Cooled, Contoured Endwall With Various Coolant Injection Rates2001
- Turbine Nozzle Endwall Film Cooling Study Using Pressure-Sensitive PaintJournal of Turbomachinery, 2001
- Film-Cooled Turbine Endwall in a Transonic Flow Field: Part I—Aerodynamic MeasurementsJournal of Turbomachinery, 2001
- Measurements in a Turbine Cascade Over a Contoured Endwall: Discrete Hole Injection of Bleed Flow2000
- Effects of Slot Bleed Injection Over a Contoured End Wall on Nozzle Guide Vane Cooling Performance: Part II — Thermal Measurements2000
- Effects of Slot Bleed Injection Over a Contoured Endwall on Nozzle Guide Vane Cooling Performance: Part I — Flow Field Measurements2000
- Flow and Heat Transfer at the Hub Endwall of Inlet Vane Passages — Experiments and Simulations2000
- Prediction and Measurement of Film Cooling Effectiveness for a First-Stage Turbine Vane Shroud1990
- Crossflows in a Turbine Cascade PassageJournal of Engineering for Power, 1980
- An Experimental Study of Heat Transfer and Film Cooling on Large-Scale Turbine EndwallsJournal of Heat Transfer, 1974