Acute distal tibiofibular syndesmosis injury: a systematic review of suture-button versus syndesmotic screw repair
Author:
Open Access
- 9 February 2012
- journal article
- review article
- Published by Springer Nature in International Orthopaedics
- Vol. 36 (6) , 1199-1206
Abstract
Purpose Recently, a new suture-button fixation device has emerged for the treatment of acute distal tibiofibular syndesmotic injuries and its use is rapidly increasing. The current systematic review was undertaken to compare the biomechanical properties, functional outcome, need for implant removal, and the complication rate of syndesmotic disruptions treated with a suture-button device with the current 'gold standard', i.e. the syndesmotic screw. Method A literature search in the electronic databases of the Cochrane Library, EMbase, Pubmed Medline, and Google Scholar, between January 1st 2000 to December 1st 2011, was conducted to identify studies in which unstable ankle fractures with concomitant distal tibiofibular syndesmotic injury were treated with either a syndesmotic screw or a suture-button device. Results A total of six biomechanical studies, seven clinical full-text studies and four abstracts on the TightRope system, and 27 studies on syndesmotic screw or bolt fixation were identified. The AOFAS of 133 patients treated with TightRope was 89.1 points, with an average study follow-up of 19 months. The AOFAS score in studies with 253 patients treated with syndesmotic screws (metallic and absorbable) or bolts was 86.3 points, with an average study follow-up of 42 months. Two studies reported an earlier return to work in the TightRope group. Implant removal was reported in 22 (10%) of 220 patients treated with a TightRope (range, 0–25%), in the screw or bolt group the average was 51.9% of 866 patients (range, 5.8–100%). Conclusion The TightRope system has a similar outcome compared with the syndesmotic screw or bolt fixation, but might lead to a quicker return to work. The rate of implant removal is lower than in the syndesmotic screw group. There is currently insufficient evidence on the long-term effects of the TightRope and more uniform outcome reporting is desirable. In addition, there is a need for studies on cost-effectiveness of the treatment of acute distal tibiofibular syndesmotic disruption treated with a suture-button device.Keywords
This publication has 60 references indexed in Scilit:
- An Anatomical Way of Treating Ankle Syndesmotic InjuriesThe Journal of Foot and Ankle Surgery, 2011
- Comparison of Different Fixation Methods of the Suture-Button Implant for Tibiofibular Syndesmosis InjuriesThe American Journal of Sports Medicine, 2011
- To retain or remove the syndesmotic screw: a review of literatureArchives of orthopaedic and trauma surgery, 2010
- Surgical treatment of syndesmotic diastasis: emphasis on effect of syndesmotic screw on ankle functionInternational Orthopaedics, 2010
- Functional and Radiographic Results of Patients with Syndesmotic Screw Fixation: Implications for Screw RemovalJournal of Orthopaedic Trauma, 2010
- Outcome after fixation of ankle fractures with an injury to the syndesmosisThe Journal of Bone and Joint Surgery. British volume, 2009
- Syndesmotic Instability in Weber B Ankle Fractures: A Clinical EvaluationJournal of Orthopaedic Trauma, 2007
- Examination and Repair of the AITFL in Transmalleolar FracturesJournal of Orthopaedic Trauma, 2006
- Adult ankle fractures—an increasing problem?Acta Orthopaedica, 1998
- Repair of the Tibiofibular Syndesmosis with a Flexible ImplantJournal of Orthopaedic Trauma, 1991