Lymphoscintigraphy is a nuclear medicine procedure that is used to detect sentinel lymph nodes (SLNs). This project sought to investigate fusion of planar scintigrams with CT topograms as a means of improving the anatomic reference for the SLN localization. Heretofore, the most common lymphoscintigraphy localization method has been backlighting with a 57Co sheet source. Currently, the most precise method of localization through hybrid SPECT/CT increases the patient absorbed dose by a factor of 34 to 585 (depending on the specific CT technique factors) over the conventional 57Co backlighting. The new approach described herein also uses a SPECT/CT scanner, which provides mechanically aligned planar scintigram and CT topogram data sets, but only increases the dose by a factor of two over that from 57Co backlighting. Planar nuclear medicine image fusion with CT topograms has been proven feasible and offers a clinically suitable compromise between improved anatomic details and minimally increased radiation dose.Keywords
Funding Information
- Siemens USA
- Department of Imaging Physics, U.T. M. D. Anderson Cancer Center
This publication has 18 references indexed in Scilit:
- Optimal 57Co Flood Source Activity and Acquisition Time for Lymphoscintigraphy Localization ImagesJournal of Nuclear Medicine Technology, 2008
- The Hybrid SPECT/CT as an Additional Lymphatic Mapping Tool in Patients with Breast CancerWorld Journal of Surgery, 2008
- Single-Photon Emission Computed Tomography/Computed Tomographyfor Sentinel Node Mapping in Breast CancerSeminars in Nuclear Medicine, 2007
- Reducing exposure from 57Co sources during breast lymphoscintigraphy by optimizing energy windows and other suggested enhancements of acquisition and the display of images.2004
- Clinical Breast Lymphoscintigraphy: Optimal Techniques for Performing Studies, Image Atlas, and Analysis of ImagesRadioGraphics, 2004
- Factors affecting visualization rates of internal mammary sentinel nodes during lymphoscintigraphy.2003
- Methods to outline the patient during lymphoscintigraphy.2003
- Improved body-outline imaging technique for localization of sentinel lymph nodes in breast surgery.2002
- Technical Aspects of Performing LymphoscintigraphyClinical Nuclear Medicine, 2000
- A combined PET/CT scanner for clinical oncology.2000