Stent-Assisted Coil Embolization of Posterior Communicating Artery Aneurysms
Authors:
Open Access
- 9 May 2013
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 34 (11) , 2171-2176
Abstract
BACKGROUND AND PURPOSE: Use of protective stents may not be effective in coil embolization of wide-neck aneurysms involving the posterior communicating artery. Successful implementation depends on the caliber of the vessel, its angle of origin, and the manner in which its orifice is incorporated into the aneurysm. Presented here are the results (clinical and radiographic) of coil embolization in aneurysms of the ICA-posterior communicating artery junction, variably aided by stents. The primary focus is angiographic configurations that impact stent placement. MATERIALS AND METHODS: From a prospective data repository, we retrieved records of 32 consecutive patients with 33 posterior communicating artery aneurysms, all of which were treated by stent-assisted coil embolization between June 2008 and August 2012. Outcomes were analyzed in terms of aneurysm configuration and clinical status. RESULTS: Stents were positioned entirely in the ICA (n = 26), from the ICA to the posterior communicating artery (n = 2), in the posterior communicating artery only (n = 3), and retrograde from the posterior communicating artery to the ICA terminus (n = 2). Procedure-related complications occurred in 3 patients (9.1%), but only 1 (3.0%) had mild neurologic sequelae (Glasgow Outcome Score 4). Using coil embolization, we achieved successful occlusion in 24 aneurysms (72.7%), and in 9 others, subtotal occlusion was conferred. During a mean follow-up of 15.7 ± 10.7 months, imaging of 27 aneurysms documented stable occlusion in 19 (70.4%), whereas angiography of 15 aneurysms (39.5%) disclosed 2 instances of in-stent stenosis (13.3%) and a solitary occurrence of stent migration (6.7%). CONCLUSIONS: In posterior communicating artery aneurysms, stent protection during coil embolization is feasible by adjusting the procedural strategy to accommodate differing configurations of the aneurysm and its vascular source.Keywords
This publication has 18 references indexed in Scilit:
- True Aneurysms of the Posterior Communicating Artery: A Systematic Review and Meta-Analysis of Individual Patient DataWorld Neurosurgery, 2011
- Preinterventional Clopidogrel Response Variability for Coil Embolization of Intracranial Aneurysms: Clinical ImplicationsAmerican Journal of Neuroradiology, 2010
- Stent-Assisted Coiling of Intracranial AneurysmsStroke, 2010
- A review of the management of posterior communicating artery aneurysms in the modern eraSurgical Neurology International, 2010
- Y-stent-assisted coil embolization for the management of unruptured cerebral aneurysms: report of six casesActa Neurochirurgica, 2009
- A New Self-Expandable Nitinol Stent for the Treatment of Wide-Neck Aneurysms: Initial Clinical ExperienceAmerican Journal of Neuroradiology, 2008
- NEUROFORM STENT-ASSISTED COIL EMBOLIZATION OF WIDE-NECK INTRACRANIAL ANEURYSMSNeurosurgery, 2007
- A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysmsNeuroradiology, 2007
- Predicting the risk of rupture of intracranial aneurysms based on anatomical locationActa Neurochirurgica, 2005
- Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatmentThe Lancet, 2003