Biological response to micron‐ and nanometer‐sized particles known as potential wear products from artificial hip joints: Part II: Reaction of murine macrophages to corundum particles of different size distributions
Authors:
- 18 June 2008
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 89A (2) , 390-401
Abstract
Macrophages play a pivotal role in tissue reaction and immune response. They recognize, phagocytose particles and generate cytokines to influence local cellular reactions. Friction and wear of implant components usually generates microparticles (MP) in a size range of 1–10 μm and nanoparticles (NP) in the range of 10–1000 nm. To investigate the possible impact of MP or NP on cellular reactions, we exposed murine macrophages (RAW264.7) to corundum MP and NP. The same mass was used in both NP and MP cell culture solutions, i.e. there were more NP than MP per identical volumes of culture solution. After 4, 24, 48, 72, and 96 h aliquots of cell culture supernatants were tested for different cytokines, growth factors and nitric oxide. Macrophages were stained with MGG (May‐Grünwald Giemsa), counted and morphologically characterized by scanning electron microscopy and transmission electron microscopy. Particles were attached to cell surfaces and phagocytosed within cells. Cells stimulated with particles or lipopolysaccharides for positive controls showed surface modifications indicating enhanced function. Although only marginal differences between negative controls and particle‐stimulated cells were observed in respect to cytokine production, exposure to corundum particles led to a decrease in the number of vital macrophages and to an increase in the number of giant cells. Corundum NP formed micron‐sized aggregates in the cell culture medium and led to the production of more giant cells than MP. Sodiumdodecylsulfate polyacrylamide gel electrophoresis of the cell culture medium with particles proved the adsorption of proteins to particles. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009Keywords
This publication has 32 references indexed in Scilit:
- Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulatorsJournal of Biomedical Materials Research Part A, 2006
- Aseptic loosening, not only a question of wear: A review of different theoriesActa Orthopaedica, 2006
- Comparison of in vitro with in vivo characteristics of wear particles from metal–metal hip implantsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2004
- Aseptic looseningGene Therapy, 2004
- Alumina–alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revisionBiomaterials, 2002
- Alumina–alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulationsBiomaterials, 2002
- Interleukin 15 production by macrophages in the implant interface membrane of aseptically loosened joint replacementsJournal of Materials Science: Materials in Medicine, 1998
- Characterization and Comparison of Wear Debris from Failed Total Hip Implants of Different Types*Journal of Bone and Joint Surgery, 1996
- Heterogeneity in cellular and cytokine profiles from multiple samples of tissue surrounding revised hip prosthesesJournal of Biomedical Materials Research, 1996
- Die Reaktion des Knochens auf Knochenzement bei der Allo-Arthroplastik der H fteArchives of orthopaedic and trauma surgery, 1972