Assessment of Remote Vital Sign Monitoring and Alarms in a Real-World Healthcare at Home Dataset
Open Access
- 28 December 2022
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 10 (1) , 37
Abstract
The importance of vital sign monitoring to detect deterioration increases during healthcare at home. Continuous monitoring with wearables increases assessment frequency but may create information overload for clinicians. The goal of this work was to demonstrate the impact of vital sign observation frequency and alarm settings on alarms in a real-world dataset. Vital signs were collected from 76 patients admitted to healthcare at home programs using the Current Health (CH) platform; its wearable continuously measured respiratory rate (RR), pulse rate (PR), and oxygen saturation (SpO2). Total alarms, alarm rate, patient rate, and detection time were calculated for three alarm rulesets to detect changes in SpO2, PR, and RR under four vital sign observation frequencies and four window sizes for the alarm algorithms’ median filter. Total alarms ranged from 65 to 3113. The alarm rate and early detection increased with the observation frequency for all alarm rulesets. Median filter windows reduced alarms triggered by normal fluctuations in vital signs without compromising the granularity of time between assessments. Frequent assessments enabled with continuous monitoring support early intervention but need to pair with settings that balance sensitivity, specificity, clinical risk, and provider capacity to respond when a patient is home to minimize clinician burden.Keywords
This publication has 31 references indexed in Scilit:
- The value of vital sign trends for detecting clinical deterioration on the wardsResuscitation, 2016
- Vital signs monitoring and nurse–patient interaction: A qualitative observational study of hospital practiceInternational Journal of Nursing Studies, 2016
- Clinical Alarms in Intensive Care Units: Perceived Obstacles of Alarm Management and Alarm Fatigue in NursesHealthcare Informatics Research, 2016
- Systematic Review of Physiologic Monitor Alarm Characteristics and Pragmatic Interventions to Reduce Alarm FrequencyJournal of Hospital Medicine, 2015
- Nursing assessment of continuous vital sign surveillance to improve patient safety on the medical/surgical unitJournal of Clinical Nursing, 2015
- Understanding Clinical Alarm SafetyCritical Care Nurse, 2015
- ‘Errors’ and omissions in paper-based early warning scores: the association with changes in vital signs—a database analysisBMJ Open, 2015
- An Evidence-Based Approach to Reduce Nuisance Alarms and Alarm FatigueBiomedical Instrumentation & Technology, 2011
- Vital SignsAJN, American Journal of Nursing, 2010
- Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance AlarmsAmerican Journal of Critical Care, 2010