Abstract
In this work, a study on failure by concrete pry-out in Crestbond shear connectors is presented. The study’s aim was the development of an expression that estimates the connection’s bearing capacity. The analyses were carried out through numerical simulations designed to reproduce the referred failure mode. Numerical and experimental results are compared and discussed in relation to the maximum force reached and the cracking aspect typical of concrete pry-out. The proposed equation corresponded well to experimental results, with a mean ratio Ptheo/Pexp equal to 0,99 and a coefficient of variation of 10%. The results found in this study indicate that the concrete pry-out expression in German Technical Approval Z-26.4-56 can also be applied to Crestbond shear connectors.Keywords
This publication has 15 references indexed in Scilit:
- Composite dowels as shear connectors for composite beams – Background to the design concept for static loadingJournal of Constructional Steel Research, 2018
- Limitations on the use of partial shear connection in composite beams with steel T-sections and uniformly spaced rib shear connectorsJournal of Constructional Steel Research, 2018
- Assessing the pry-out resistance of open rib shear connectors in cracked concrete – Engineering model with aggregate interlockEngineering Structures, 2017
- The model for a general composite section resulting from the introduction of composite dowelsSteel Construction, 2017
- Composite dowels as shear connectors for composite beams – background to the German technical approvalSteel Construction, 2016
- Parametric study on shear capacity of circular-hole and long-hole perfobond shear connectorJournal of Constructional Steel Research, 2016
- Concrete fatigue in composite dowelsStructural Concrete, 2015
- The behaviour of puzzle-shaped composite dowels — Part II: Theoretical investigationsJournal of Constructional Steel Research, 2014
- The behaviour of puzzle-shaped composite dowels — Part I: Experimental studyJournal of Constructional Steel Research, 2014
- Bolted shear connectors vs. headed studs behaviour in push-out testsJournal of Constructional Steel Research, 2013