Correction Method and Software for Image Distortion and Nonuniform Response in Charge-Coupled Device-Based X-ray Detectors Utilizing X-ray Image intensifier
Authors:
- Kazuki ItoKIKazuki Ito
- Yoshiyuki AmemiyaYAYoshiyuki Amemiya
- 1 December 2005
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 44 (12R) , 8684
Abstract
An on-site method of correcting the image distortion and nonuniform response of a charge-coupled device (CCD)-based X-ray detector was developed using the response of the imaging plate as a reference. The CCD-based X-ray detector consists of a beryllium-windowed X-ray image intensifier (Be-XRII) and a CCD as the image sensor. An image distortion of 29% was improved to less than 1% after the correction. In the correction of nonuniform response due to image distortion, subpixel approximation was performed for the redistribution of pixel values. The optimal number of subpixels was also discussed. In an experiment with polystyrene (PS) latex, it was verified that the correction of both image distortion and nonuniform response worked properly. The correction for the “contrast reduction” problem was also demonstrated for an isotropic X-ray scattering pattern from the PS latex.Keywords
This publication has 22 references indexed in Scilit:
- Activation Mechanisms of Transcriptional Regulator CooA Revealed by Small-angle X-ray ScatteringJournal of Molecular Biology, 2004
- Spatial distribution of lamella structure in PCL/PVB band spherulite investigated with microbeam small- and wide-angle X-ray scatteringPolymer, 2003
- Fast Compaction of α-Lactalbumin During Folding Studied by Stopped-flow X-ray ScatteringJournal of Molecular Biology, 2002
- Fluctuations of lamellar structure prior to atransition in a nonionic surfactant systemPhysical Review E, 2000
- The use of a Hamamatsu X-ray image intensifier with a cooled CCD as a solution X-ray scattering detectorJournal of Synchrotron Radiation, 1999
- Tests of a prototype pixel array detector for microsecond time-resolved X-ray diffractionJournal of Synchrotron Radiation, 1999
- Structure Change of Glass-like Carbon with Heat Treatment, Studied by Small Angle X-Ray Scattering: I. Glass-like Carbon Prepared from Phenolic ResinJapanese Journal of Applied Physics, 1998
- A Novel Technique for Accurate Intensity Calibration of Area X-ray Detectors at Almost Arbitrary EnergyJournal of Synchrotron Radiation, 1996
- Calibration and correction of distortions in two-dimensional detector systemsa)Review of Scientific Instruments, 1995
- Large-aperture TV detector with a beryllium-windowed image intensifier for x-ray diffractionReview of Scientific Instruments, 1995