Organizational model and reactions to alerts in remote monitoring of cardiac implantable electronic devices: A survey from the Home Monitoring Expert Alliance project
Open Access
- 12 November 2018
- journal article
- research article
- Published by Wiley in Clinical Cardiology
- Vol. 42 (1) , 76-83
Abstract
Background: This survey aimed to describe the organizational workflow of cardiac implantable electronic devices (CIEDs) remote monitoring (RM) service in ordinary practice.Methods: A questionnaire was designed for our purpose and completed by 49 sites participating to the Italian Home Monitoring Expert Alliance.Results: A dedicated organizational model for RM was set up for 86% of centers. The median RM team consisted of 2 (Interquartile range [IQR]: 1‐3) physicians and 1 (IQR: 0‐2) nurse. RM service was available in working hours and the median percentage of patients included was 100% (IQR: 10%‐100%) for implantable cardioverter‐defibrillator (ICD) and cardiac resynchronization therapy (CRT) recipients and 5% (IQR:0%‐30%) for pacemakers. In‐office follow‐up was performed every 12 and 6 months for pacemaker and ICD/CRT recipients, respectively. More than 90% of sites used to activate all technical alerts, with a prompt reaction in case of an out‐of‐range parameter. The threshold for atrial fibrillation (AF) daily burden notification in most cases ranged from 2.4 to 7.2 hours. All ventricular arrhythmias alerts were usually switched on: an inappropriate therapy or more than one appropriate episode triggered an urgent in‐hospital visit. Concerning heart failure, low CRT percentage pacing alert was always used, while the other available notifications were less frequently switched on.Conclusions: This survey showed that RM service was usually set up with a primary nursing model including on average two responsible physicians and one nurse and mainly offered to ICD/CRT patients. Technical, AF and ventricular arrhythmia alerts triggered prompt reactions, while heart failure related indexes were generally less applied.Keywords
This publication has 31 references indexed in Scilit:
- Effectiveness of remote monitoring of CIEDs in detection and treatment of clinical and device-related cardiovascular events in daily practice: the HomeGuide RegistryEP Europace, 2013
- A randomized study of remote follow-up of implantable cardioverter defibrillators: safety and efficacy report of the ECOST trialEuropean Heart Journal, 2012
- Remote follow-up of pacemakers in a selected population of debilitated elderly patientsEP Europace, 2012
- A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)European Heart Journal, 2011
- Actions elicited during scheduled and unscheduled in-hospital follow-up of cardiac devices: results of the ATHENS multicentre registryEP Europace, 2011
- Healthcare personnel resource burden related to in-clinic follow-up of cardiovascular implantable electronic devices: a European Heart Rhythm Association and Eucomed joint surveyEP Europace, 2011
- Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-UpCirculation, 2010
- Automatic Remote Monitoring of Implantable Cardioverter-Defibrillator Lead and Generator PerformanceCirculation: Arrhythmia and Electrophysiology, 2010
- Combined Heart Failure Device Diagnostics Identify Patients at Higher Risk of Subsequent Heart Failure HospitalizationsJACC, 2010
- The Relationship Between Daily Atrial Tachyarrhythmia Burden From Implantable Device Diagnostics and Stroke RiskCirculation: Arrhythmia and Electrophysiology, 2009