To measure burning rates of solid propellants, the strand burner method is widely adopted as a standard method. The strand burner method measures burning rates under the constant pressure, so it requires a number of measurements to determine the burning rates over all pressure range. However, ultrasonic technique can measure burning rates as a function of pressure in single test, since it performed under a constant volume condition. But, we measured that burning rates by ultrasonic technique have deviation that is bigger than 3% from average one. In this study, to reduce the deviation, we have investigated variation in material property of solid propellants. And then we analyze the relation between variations of the burning rates and material property. Also, we have predicted effects of non-linear burning surface using simulated ultrasonic signals.