Intraoperative Neuromonitoring and Alarm Criteria for Judging MEP Responses to Transcranial Electric Stimulation: The Threshold-Level Method
Author:
- 1 January 2017
- journal article
- review article
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 34 (1) , 12-21
Abstract
Summary: The motor evoked potential (MEP) is used in the operating room to gauge—and ultimately protect—the functional integrity of the corticospinal tract (CST). However, there is no consensus as to how to best interpret the MEP for maximizing its sensitivity and specificity to CST compromise. The most common way is to use criteria associated with response magnitude (response amplitude; waveform complexity, etc.). With this approach, should an MEP in response to a fixed stimulus intensity diminish below some predetermined cutoff, suggesting CST dysfunction, then the surgical team is warned. An alternative approach is to examine the minimum stimulus energy—the threshold—needed to elicit a minimal response from a given target muscle. Threshold increases could then be used as an alternative basis for evaluating CST functional integrity. As the original proponent of this Threshold-Level alarm criteria for MEP monitoring during surgery, I have been asked to summarize the basis for this method. In so doing, I have included justification for what might seem to be arbitrary recommendations. Special emphasis is placed on anesthetic considerations because these issues are especially important when weak stimulus intensities are called for. Finally, it is important to emphasize that all the alarm criteria currently in use for interpreting intraoperative MEPs have been shown to be effective for protecting CST axons during surgery. Although differences between approaches are more than academic, overall it is much better for patient welfare to be using some form of MEP monitoring than to use none at all, while you wait for consensus about alarm criteria to emerge.Keywords
This publication has 46 references indexed in Scilit:
- Optimum interpulse interval for transcranial electrical train stimulation to elicit motor evoked potentials of maximal amplitude in both upper and lower extremity target musclesClinical Neurophysiology, 2013
- Clinical Predictors of Recovery after Blunt Spinal Cord Trauma: Systematic ReviewJournal of Neurotrauma, 2011
- Successful Monitoring of Transcranial Electrical Motor Evoked Potentials With Isoflurane and Nitrous Oxide in Scoliosis SurgeriesSpine, 2010
- False Negative and Positive Motor Evoked Potentials in One Patient: Is Single Motor Evoked Potential Monitoring Reliable Method?Spine, 2010
- False-Negative Transcranial Motor-Evoked Potentials During Scoliosis Surgery Causing ParalysisSpine, 2009
- Action potential generation requires a high sodium channel density in the axon initial segmentNature Neuroscience, 2008
- Axon Initial Segment Kv1 Channels Control Axonal Action Potential Waveform and Synaptic EfficacyNeuron, 2007
- Intraoperative Motor-evoked Potential Monitoring in Scoliosis Surgery: Comparison of Desflurane/Nitrous Oxide With Propofol Total Intravenous Anesthetic RegimensJournal of Neurosurgical Anesthesiology, 2006
- Abductor hallucis for monitoring lower-limb recovery after spinal cord injury in manSpinal Cord, 2004
- Acute traumatic central cord syndrome: MRI-pathological correlationsNeuroradiology, 1992