Mapping the fine structure of cortical activity with different micro-ECoG electrode array geometries
Authors:
- Xi WangXWXi Wang
- C Alexis GkogkidisCGC Alexis Gkogkidis
- Olga IljinaOIOlga Iljina
- Lukas D J FiedererLFLukas D J Fiederer
- Christian HenleCHChristian Henle
- Irina MaderIMIrina Mader
- Jan KaminskyJKJan Kaminsky
- Thomas StieglitzThomas Stieglitz
- Mortimer GierthmuehlenMGMortimer Gierthmuehlen
- Tonio BallTBTonio Ball
Open Access
- 16 August 2017
- journal article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 14 (5) , 056004
Abstract
Innovations in micro-electrocorticography (µECoG) electrode array manufacturing now allow for intricate designs with smaller contact diameters and/or pitch (i.e. inter-contact distance) down to the sub-mm range. The aims of the present study were: (i) to investigate whether frequency ranges up to 400 Hz can be reproducibly observed in µECoG recordings and (ii) to examine how differences in topographical substructure between these frequency bands and electrode array geometries can be quantified. We also investigated, for the first time, the influence of blood vessels on signal properties and assessed the influence of cortical vasculature on topographic mapping. The present study employed two µECoG electrode arrays with different contact diameters and inter-contact distances, which were used to characterize neural activity from the somatosensory cortex of minipigs in a broad frequency range up to 400 Hz. The analysed neural data were recorded in acute experiments under anaesthesia during peripheral electrical stimulation. We observed that µECoG recordings reliably revealed multi-focal cortical somatosensory response patterns, in which response peaks were often less than 1 cm apart and would thus not have been resolvable with conventional ECoG. The response patterns differed by stimulation site and intensity, they were distinct for different frequency bands, and the results of functional mapping proved independent of cortical vascular. Our analysis of different frequency bands exhibited differences in the number of activation peaks in topographical substructures. Notably, signal strength and signal-to-noise ratios differed between the two electrode arrays, possibly due to their different sensitivity for variations in spatial patterns and signal strengths. Our findings that the geometry of µECoG electrode arrays can strongly influence their recording performance can help to make informed decisions that maybe important in number of clinical contexts, including high-resolution brain mapping, advanced epilepsy diagnostics or brain-machine interfacing.Keywords
Funding Information
- German Federal Ministry of Education and Research (BMBF) (grant 01GQ1510 OptiStim, grant 13GW0053D MotorBic)
- Deutsche Forschungsgemeinschaft (DFG) (grant EXC1086 BrainLinks-BrainTools)
This publication has 120 references indexed in Scilit:
- Spontaneous High-Gamma Band Activity Reflects Functional Organization of Auditory Cortex in the Awake MacaqueNeuron, 2012
- Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivoNature Neuroscience, 2011
- Decoding the rat forelimb movement direction from epidural and intracortical field potentialsJournal of Neural Engineering, 2011
- Decoding spoken words using local field potentials recorded from the cortical surfaceJournal of Neural Engineering, 2010
- Microseizures and the spatiotemporal scales of human partial epilepsyBrain, 2010
- Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronicsNature Materials, 2010
- Optimal spacing of surface electrode arrays for brain–machine interface applicationsJournal of Neural Engineering, 2010
- Desflurane Selectively Suppresses Long-latency Cortical Neuronal Response to Flash in the RatAnesthesiology, 2009
- High-frequency oscillations in human temporal lobe: simultaneous microwire and clinical macroelectrode recordingsBrain, 2008
- Micro-field evoked potentials recorded from the porcine sub-dural cortical surface utilizing a microelectrode arrayJournal of Neuroscience Methods, 2007