Optimizing Colonic Distention for Multi–Detector Row CT Colonography: Effect of Hyoscine Butylbromide and Rectal Balloon Catheter
Authors:
- Stuart A. TaylorSTStuart A. Taylor
- Steve HalliganSHSteve Halligan
- Vicky GohVGVicky Goh
- Simon MorleySMSimon Morley
- Paul BassettPBPaul Bassett
- Wendy AtkinWAWendy Atkin
- Clive I. BartramCBClive I. Bartram
- 1 October 2003
- journal article
- clinical trial
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 229 (1) , 99-108
Abstract
To investigate the effects of hyoscine butylbromide and an inflatable rectal balloon catheter on luminal distention during computed tomographic (CT) colonography. One hundred thirty-six subjects undergoing CT colonography were randomized to receive either 20 mg or 40 mg of hyoscine butylbromide or no spasmolytic. Subjects were also independently randomized to undergo CT colonography with an inflatable rectal balloon catheter or a standard thin rectal tube. Multi-detector row CT colonography was performed with patients in prone and supine positions, with colonic segmental distention assessed by a single observer with a four-point scale. A simple assessment of whether distention was adequate for clinical interpretation was also made, and the effect of hyoscine butylbromide and catheter use was examined by using multivariate ordered logistic regression. Administration of hyoscine butylbromide was associated with significantly improved cecal (P =.05), ascending (P =.001), and transverse (P <.001) colonic distention when patients were supine and improved ascending (P <.001) and descending (P <.001) colonic distention when patients were prone. Compared with control subjects, patients given a spasmolytic had odds of 6.49 for clinically adequate distention throughout all colonic segments (P =.001). There was no incremental advantage with use of a 40-mg dose. In contrast, rectal balloon catheter use was not significantly associated with improved distention. Hyoscine butylbromide improves colonic distention during CT colonography and should be routinely administered where it is available. Use of a thin rectal tube for insufflation is adequate.Keywords
This publication has 15 references indexed in Scilit:
- CT colonography: colonic distention improved by dual positioning but not intravenous glucagonEuropean Radiology, 2002
- Bowel wall visualisation at CT colonographyActa Radiologica, 2002
- CT colonography: Data acquisition and patient preparation techniquesSeminars in Ultrasound, CT and MRI, 2001
- Optimization of CT Colonography Technique: Prospective Trial in 180 PatientsRadiology, 2000
- The usefulness of glucagon hydrochloride for colonic distention in CT colonography.American Journal of Roentgenology, 1999
- CT colonography: value of scanning in both the supine and prone positions.American Journal of Roentgenology, 1999
- Minimisation: the platinum standard for trials?BMJ, 1998
- Retention balloon catheters and barium enemas: Attitudes, current practice and relative safety in the UKClinical Radiology, 1997
- Use of antispasmodic drugs in double contrast barium enema examination: Glucagon or buscopan?Clinical Radiology, 1995
- Routine use of hyoscine N butylbromide (buscopan) in double contrast barium enema examinationsClinical Radiology, 1982