Super-absorbent dressings: how do they perform in vitro?
Authors:
- 7 November 2012
- journal article
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 21 (Sup20) , S14-S19
Abstract
The free swell and absorption capacity under compression of six wound dressings that are indicated for moderately to highly exuding wounds was investigated. Measuring in vitro the absorptive capacity and retention under compression is important in terms of clinical efficacy and efficiency. This in vitro comparative study demonstrated that sorbion sachet EXTRA had the highest free swell capacity of the six test dressings and absorbed more than twice the volume (126%) of the test solution than its nearest competitor. When measuring capacity under compression, sorbion sachet EXTRA absorbed 88% more fluid than the nearest competitor.Keywords
This publication has 6 references indexed in Scilit:
- Wound dressings: 21st century performance requirementsJournal of Wound Care, 2010
- Laboratory findings on the exudate-handling capabilities of cavity foam and foam-film dressingsJournal of Wound Care, 2010
- Importance of moisture balance at the wound-dressing interfaceJournal of Wound Care, 2003
- The development of a novel technique for predicting the exudate handling properties of modern wound dressingsJournal of Tissue Viability, 2001
- Odour-absorbing dressingsJournal of Wound Care, 1998
- Water vapour permeance: a meaningful measure for water vapour permeability of wound coveringsBurns, 1989