Fire Performance of Self-Tapping Screws in Tall Mass-Timber Buildings
Open Access
- 16 April 2021
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 11 (8) , 3579
Abstract
Building elements are required to provide sufficient fire resistance based on requirements set forth in the National Building Code of Canada (NBCC). Annex B of the Canadian standard for wood engineering design (CSA O86-19) provides a design methodology to calculate the structural fire-resistance of large cross-section timber elements. However, it lacks at providing design provisions for connections. The objectives of this study are to understand the fire performance of modern mass timber fasteners such as self-tapping screws, namely to evaluate their thermo-mechanical behavior and to predict their structural fire-resistance for standard fire exposure up to two hours, as would be required for tall buildings in Canada. The results present the great fire performance of using self-tapping screws under a long time exposure on connections in mass timber construction. The smaller heated area of the exposed surface has limited thermal conduction along the fastener’s shanks and maintained their temperature profiles relatively low for two hours of exposure. Based on the heat-affected area, the study presents new design principles to determine the residual length of penetration that would provide adequate load-capacity of the fastener under fire conditions. It also allows determining safe fire-resistance values for unprotected fasteners in mass timber construction exposed up to two hours of standard fire exposure.Keywords
Funding Information
- Collaborative Research and Development Grants - Project (524504–18)
- Industrial Research Chairs - Regular - Research (461745–18)
This publication has 22 references indexed in Scilit:
- Theoretical Evaluation of Moment Resistance for Bolted Timber ConnectionsMATEC Web of Conferences, 2019
- Structural fire performance of wood-steel-wood bolted connections with and without perpendicular-to-wood grain reinforcementJournal of Structural Fire Engineering, 2019
- Review of experimental data for timber connections with dowel-type fasteners under standard fire exposureFire Safety Journal, 2019
- Determination of fire resistance ratings for glulam connectors within US high rise timber buildingsFire Safety Journal, 2017
- Fire resistance of primary beam – secondary beam connections in timber structuresJournal of Structural Fire Engineering, 2016
- Challenges and strategies for urban green-space planning in cities undergoing densification: A reviewUrban Forestry & Urban Greening, 2015
- Performance of Timber Connections Exposed to Fire: A ReviewFire Technology, 2013
- Fire Performance of Timber Connections, Part 1: Fire Resistance Tests on Bolted Wood-Steel-Wood and Steel-Wood-Steel ConnectionsJournal of Structural Fire Engineering, 2012
- Incident heat flux measurements in floor and wall furnaces of different sizesFire and Materials, 2005
- Mechanical properties of structural steel at elevated temperatures and after cooling downFire and Materials, 2004