Inter-rater and inter-instrument reliability of goniometric thumb active and passive flexion range of motion measurements in healthy hands
Authors:
- 21 April 2017
- journal article
- research article
- Published by SAGE Publications in Hand Therapy
- Vol. 22 (3) , 110-117
Abstract
Introduction: Goniometry is a common measure of range of motion and may be assessed by different therapists and goniometers. To date, there is limited psychometric data on active and passive range of motion measurements of individual thumb joints. The purpose of this study was to analyze inter-rater and inter-instrument reliability of passive and active flexion goniometric measures of thumb joints in healthy adults. Methods: A within-subjects psychometric design was utilized. Two raters each used two goniometers (Baseline™ Flexion-Hyper Extension and Baseline™ 180 Degree Digit) to measure each participant’s (n = 48) thumb carpometacarpal, metacarpophalangeal, and interphalangeal flexion range of motion. Inter-rater and inter-instrument reliability and stability were evaluated through use of intraclass correlation coefficient, standard error of the measurement, and minimal detectable change test statistics. Results: Inter-rater reliability was poor for carpometacarpal flexion and good-to-excellent for metacarpophalangeal and IP flexion. Between-rater error ranged between 3.9 and 6.3 degrees for active measurements and between 3.9 and 7.9 degrees for passive. Error was generally less when using the Baseline™ 180 Degree Digit goniometer. Inter-instrument reliability was excellent for all joints. Discussion: These findings validate the concerns that thumb goniometry inter-rater reliability may differ in clinical and non-clinical populations, support further study in clinical populations, and support a common assumption that the same rater should test the same client with the same goniometer to minimize measurement error. When compared to the Baseline™ Flexion-Hyper Extension Goniometer, the Baseline™ 180 Degree Digit had higher repeatability across raters. Further research on within-rater reliability is required as is study on clinical populations.Keywords
This publication has 23 references indexed in Scilit:
- Reliability of the standard goniometry and diagrammatic recording of finger joint angles: a comparative study with healthy subjects and non-professional ratersBMC Musculoskeletal Disorders, 2013
- Interrater Reliability in Finger Joint Goniometer Measurement in Dupuytren’s DiseaseAmerican Journal of Occupational Therapy, 2012
- The three-dimensional analysis of three thumb joints coordination in activities of daily livingClinical Biomechanics, 2011
- Palmar Abduction: Reliability of 6 Measurement Methods in Healthy AdultsThe Journal of Hand Surgery, 2009
- Inter-rater and Intra-rater Reliability when Measuring Interphalangeal JointsPhysiotherapy, 2003
- Goniometry of the proximal and distal interphalangeal joints, part II: Placement preferences, interrater reliability, and concurrent validityJournal of Hand Therapy, 2001
- Comparison of Visual Estimation and Goniometry for Assessment of Metacarpophalangeal Joint AnglePhysiotherapy, 1999
- The Reliability of Goniometric Measurements of Active and Passive Wrist MotionsAmerican Journal of Occupational Therapy, 1990
- Functional range of motion of the joints of the handThe Journal of Hand Surgery, 1990
- Variability and reliability of joint measurementsThe American Journal of Sports Medicine, 1990