Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures
Authors:
Preprint
Abstract
In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of Penning-like energy-transfer processes. The effect is present at all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3 %. Operating in this concentration range, the maximum gain reached values as high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable for 22.1 keV X-rays is substantially better than the one previously obtained in pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of interest for calorimetric applications of high pressure gas Xe TPCs, in particular for the search of the neutrinoless double beta decay of Xe-136. The resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value of Xe-136 for 1 (10) bar.Keywords
All Related Versions
This publication has 21 references indexed in Scilit:
- Status of R&D on Micromegas for Rare Event Searches : The T-REX projectEAS Publications Series, 2012
- Radiopurity of micromegas readout planesAstroparticle Physics, 2011
- Micromegas readouts for double beta decay searchesJournal of Cosmology and Astroparticle Physics, 2010
- Energy resolution of alpha particles in a microbulk Micromegas detector at high pressure argon and xenon mixturesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- A new concept for streamer quenching in resistive plate chambersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- Development of a double-phase Xenon cell using micromegas charge readout for applications in dark matter physicsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- MICROMEGAS: a high-granularity position-sensitive gaseous detector for high particle-flux environmentsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Xenon-based Penning mixtures for proportional countersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1989
- Gas gain in xenon + 2,3 dimethyl-2-butene filled proportional countersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1987
- Statistics of electron avalanches and ultimate resolution of proportional countersNuclear Instruments and Methods, 1970