Development of a Graphene-Oxide-Deposited Carbon Electrode for the Rapid and Low-Level Detection of Fentanyl and Derivatives
Open Access
- 9 September 2022
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (37) , 12706-12714
Abstract
The opioid overdose crisis in North America worsened during the COVID-19 pandemic, with multiple jurisdictions reporting more deaths per day due to the fentanyl-contaminated drug supply than COVID-19. The rapid quantitative detection of fentanyl in the illicit opioid drug supply or in bodily fluids at biologically relevant concentrations (i.e., <80 nM) remains a significant challenge. Electroanalytical techniques are inexpensive and can be used to rapidly detect fentanyl, but detection limits need to be improved. Herein, we detail the development of an electrochemical-based fentanyl analytical detection strategy that used a glassy carbon electrode modified with electrochemically reduced graphene oxide (ERGO) via electrophoretic deposition. The resulting surface was further electrochemically reduced in the presence of fentanyl to enhance the sensitivity. Multiple ERGO thicknesses were prepared in order to prove the versatility and ability to fine-tune the layer to the desired response. Fentanyl was detected at <10 ppb (<30 nM) with a limit of detection of 2 ppb and a calibration curve that covered 4 orders of concentration (from 1 ppb to 10 ppm). This method was sensitive to fentanyl analogues such as carfentanil. Interference from the presence of 100-fold excess of other opioids (heroin, cocaine) or substances typically found in illicit drug samples (e.g. caffeine and sucrose) was not significant.Keywords
Funding Information
- VGH and UBC Hospital Foundation
- Natural Sciences and Engineering Research Council of Canada (RGPIN 2016-05528)
- Mitacs (IT23138)
- University of British Columbia
This publication has 28 references indexed in Scilit:
- Ionic Liquid-Modified Disposable Electrochemical Sensor Strip for Analysis of FentanylAnalytical Chemistry, 2019
- Improved Admixture Vaccine of Fentanyl and Heroin Hapten Immunoconjugates: Antinociceptive Evaluation of Fentanyl-Contaminated HeroinACS Omega, 2018
- DARK Classics in Chemical Neuroscience: FentanylACS Chemical Neuroscience, 2018
- Mortality risk during and after opioid substitution treatment: systematic review and meta-analysis of cohort studiesBMJ, 2017
- Review: The Application of Liquid Chromatography Electrochemical Detection for the Determination of Drugs of AbuseSeparations, 2016
- Electrochemical Impedance Spectroscopy and its Applications2014
- Determination of illicit drugs and related substances by high-performance liquid chromatography with an electrochemical coulometric-array detectorJournal of Chromatography A, 1996
- Kinetic measurements of a surface confined redox reactionAnalytica Chimica Acta, 1995
- Square-wave voltammetry of quasi-reversible surface redox reactionsJournal of Electroanalytical Chemistry, 1995
- Liquid chromatography of opium alkaloids, heroin, cocaine, and related compounds using electrochemical detectionAnalytical Chemistry, 1985