Density Changes in Thermometer Glasses
Authors:
- 1 March 1952
- journal article
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 35 (3) , 67-72
Abstract
A study was made of the density changes in the thermometer glasses, Corning 0041, 7560, 1720 and an experimental glass, Corning EXP175EK. Thermometers fabricated from these glasses were given similar heat‐treatments in their respective annealing ranges. Measurements were then made of the ice point changes at various fixed temperatures from room temperature to the normal upper useful limits of the glasses. Holding periods extended to 1 year. The ice point change in a thermometer is a measure of the per cent density change in the glass from which the bulb is fabricated. The relation of this change in density to temperature for a given duration of roasting appears to be well represented by two curves of the form of a constant times a temperature to a power. The value of the power appears to change rather abruptly at some temperature, T 0 , in the neighborhood of 150°C. below the strain point temperature and to be constant in the regions on either side of T 0 . At equal temperatures below the strain point the behavior of the glasses is quite similar.Keywords
This publication has 7 references indexed in Scilit:
- RELATION BETWEEN INELASTIC DEFORMABILITY AND THERMAL EXPANSION OF GLASS IN ITS ANNEALING RANGE*Journal of the American Ceramic Society, 1946
- Relaxation of stresses in annealing glassJournal of Research of the National Bureau of Standards, 1945
- AGING THERMOMETERS*Journal of the American Ceramic Society, 1944
- STRUCTURAL HOMOGENEITY OF GLASS*Journal of the American Ceramic Society, 1943
- TRANSFORMATION REGION OF GLASS*Journal of the American Ceramic Society, 1943
- The Relation between the Composition and the Density and Optical Properties of Glass I The Soda-Lime-Silica GlassesJournal of the Optical Society of America, 1932
- Heat treatment of high-temperature mercurial thermometersBulletin of the Bureau of Standards, 1906