Changes in interpretation of spirometry by implementing the GLI 2012 reference equations: impact on patients tested in a hospital-based PFT lab in a large metropolitan city
Open Access
- 8 December 2022
- journal article
- research article
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 9 (1) , e001389
Abstract
Background: The Global Lung Function Initiative (GLI-2012) focused on race/ethnicity as an important factor in determining reference values. This study evaluated the effects of changing from Canadian reference equations developed from an all-Caucasian cohort with European ancestry to the GLI-2012 on the interpretation of spirometry in a multiethnic population and aimed to identify the ethnic groups affected by discrepant interpretations. Methods: Clinically indicated spirometry in a multiethnic population (aged 20–80 years) collected from 2018 to 2021 was analysed. The predicted and lower limit of normal (LLN) values were calculated using three sets of reference equations: Canadian, GLI-race/ethnic-based (GLI-Race) and GLI-race/ethnic-neutral (GLI-Other). We compared the prevalence of concordance in the abnormal diagnoses (defined as 1), and FEV1/FVC among the three reference values, and evaluated whether race/ethnicity was associated with discordance. Results: Data from 406 participants were evaluated (non-Caucasian 43.6%). There was 85%–87% concordance for normal/abnormal FVC and FEV1 interpretations among the Canadian, GLI-Race and GLI-Other reference equations. In all ethnic groups, application of the Canadian references for interpretation led to a higher prevalence of abnormal (1compared with GLI-Race and GLI-Other. This trend was more prominent in Black, South-East Asian and Mixed/other ethnic groups when comparing the Canadian to the GLI-Race equations. In contrast, the discordance rates were similar among ethnic groups when compared with the GLI-Other reference equations. Interpretation of FEV1/FVC had a high rate of agreement among all equations. Conclusion: Interpretation using Canadian reference equations was associated with a higher prevalence of restrictive physiology compared with the GLI-2012 equations, particularly if the GLI-Race were used. These observations were mostly found in non-white Caucasian groups, highlighting the need to choose reference equations that reflect closely the ethnic mix of the population being evaluated in order to optimise patient management.Keywords
Funding Information
- CIHR-Natural Sciences and Engineering REeseach Council (N/A)
- Nakayama Foundation for Human Science (N/A)
- Collaborative Health Research Programme (415013)
- Lung Health Foundation (N/A)
- CIHR (4518060)
This publication has 36 references indexed in Scilit:
- Effects of Adopting the New Global Lung Function Initiative 2012 Reference Equations on the Interpretation of SpirometryRespiration, 2013
- The Global Lung Initiative 2012 reference values reflect contemporary Australasian spirometryRespirology, 2012
- Multi-ethnic reference values for spirometry for the 3–95-yr age range: the global lung function 2012 equationsEuropean Respiratory Journal, 2012
- Stitching and switching: the impact of discontinuous lung function reference equations: Figure 1–European Respiratory Journal, 2012
- “Race Correction” in Pulmonary-Function TestingNew England Journal of Medicine, 2010
- Comparison of Pulmonary Function in Immigrant vs US-Born Asian IndiansChest, 2010
- Reference equations for spirometry from a general population sample in central ItalyRespiratory Medicine, 2007
- Interpretative strategies for lung function testsEuropean Respiratory Journal, 2005
- Influence of socioeconomic status on lung function and prediction equations in Indian childrenPediatric Pulmonology, 2005
- Spirometric Reference Values from a Sample of the General U.S. PopulationAmerican Journal of Respiratory and Critical Care Medicine, 1999