Use of Magnets as a Minimally Invasive Approach for Anastomosis in Esophageal Atresia: Long-Term Outcomes
- 1 October 2019
- journal article
- research article
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 29 (10) , 1202-1206
Abstract
Introduction: The majority of esophageal atresia (EA) patients undergo surgical repair soon after birth. However, factors due to patient characteristics, esophageal length, or surgical complications can limit the ability to obtain esophageal continuity. A number of techniques have been described to treat these patients with “long-gap” EA. Magnets are a nonsurgical alternative for esophageal anastomosis. The purpose of this study was to report long-term outcomes for the use of magnets in EA. Materials and Methods: Between July 2001 and December 2017, 13 patients underwent placement of a magnetic catheter-based system under fluoroscopic guidance at six institutions. Daily chest radiographs were obtained until there was union of the magnets. Magnets were then removed and replaced with an oro- or nasogastric tube. Complications and outcomes were recorded. The average length of follow-up was 9.3 years (range 1.42–17.75). Results: A total of 85% of the patients had type A, pure EA, and 15% had type C with previous fistula ligation. The average length of time to achieve anastomosis was 6.3 days (range 3–13). No anastomotic leaks occurred, and all of the patients had an expected esophageal stenosis that required dilation given the 10F coupling surface of the magnets (average 9.8, range 3–22). Six patients (46%) had retrievable esophageal stents, and two underwent surgery; yet all maintained their native esophagus without interposition. A total of 92% were on full oral feeds at the time of follow-up. Conclusion: The use of magnets for treatment of long-gap EA is safe and feasible and accomplished good long-term outcomes. The main complication was esophageal stricture, although all patients maintained their native esophagus. A prospective observational study is currently enrolling patients to evaluate the safety and benefit of a catheter-based magnetic device for EA.Keywords
This publication has 22 references indexed in Scilit:
- Staged Thoracoscopic Repair of Long-Gap Esophageal Atresia Without Temporary GastrostomyJournal of Laparoendoscopic & Advanced Surgical Techniques, 2018
- Basic Knowledge of Tracheoesophageal Fistula and Esophageal AtresiaAdvances in Neonatal Care, 2018
- Experience with Thoracoscopic Repair of Long Gap Esophageal Atresia in NeonatesJournal of Laparoendoscopic & Advanced Surgical Techniques, 2015
- Thoracoscopic traction technique in long gap esophageal atresia: entering a new eraSurgical Endoscopy, 2015
- Difficult esophageal atresia: Trick and treatSeminars in Pediatric Surgery, 2014
- Mechanical Traction Techniques for Long-Gap Esophageal Atresia: A Critical AppraisalEuropean Journal of Pediatric Surgery, 2013
- Delayed primary anastomosis for management of long-gap esophageal atresia: a meta-analysis of complications and long-term outcomePediatric Surgery International, 2012
- Thoracoscopic elongation of the esophagus in long gap esophageal atresiaJournal of Pediatric Surgery, 2007
- Experience with distal circular myotomy for long-gap esophageal atresiaJournal of Pediatric Surgery, 1996
- Multistaged extrathoracic esophageal elongation for long gap esophageal atresiaJournal of Pediatric Surgery, 1994