Repeatability of echocardiographic measurements in the human fetus
Open Access
- 1 October 2002
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 20 (4) , 332-339
Abstract
Objectives: To determine the repeatability of cross‐sectional, M‐mode and Doppler echocardiographic measurements in the human fetus.Methods: This was a prospective echocardiographic study of 10 normal fetuses, involving measurement of 32 different echocardiographic variables in each. The intra‐ and interobserver error of measurements were quantified. The median (range) gestational age was 23 (17–34) weeks.Results: Cross‐sectional echocardiography: for left ventricular end‐diastolic volume the intraobserver coefficient of variation was 13% and the interobserver limits of agreement were a ratio of 0.46–2.19. For left ventricular ejection fraction the repeatability was ± 8.8% and the interobserver limits of agreement were ± 20%. M‐mode echocardiography: the coefficient of variation for left ventricular end‐diastolic dimension was 10%, and the interobserver limits of agreement were a ratio of 0.74–1.70. The intraobserver repeatability of left ventricular fractional shortening was ± 8.8%, and interobserver limits of agreement ± 15%. Limits of agreement for M‐mode‐derived left ventricular end‐diastolic volume were wide, intraobserver coefficient of variation 32% and interobserver limits were a ratio of 0.44–4.36. Doppler echocardiography: the intra‐ and interobserver errors were high for Doppler variables such as acceleration time, acceleration slope, stroke volume, cardiac output and vessel dimension. There was less error associated with measurements such as maximum Doppler velocity, velocity time integral, ejection time and heart rate.Conclusions: The repeatability of most echocardiographic measurements in the fetus is poor. This applies particularly to volumetric data such as ventricular volumes and volume flow estimations. Interobserver errors are consistently higher than intraobserver errors, confirming that when sequential measurements are clinically important, the same observer should be used. Copyright © 2002 International Society of Ultrasound in Obstetrics and GynecologyKeywords
This publication has 23 references indexed in Scilit:
- Blood flow velocity waveforms of the fetal pulmonary artery and the ductus arteriosus: reference ranges from 13 weeks to termUltrasound in Obstetrics & Gynecology, 2000
- Determination ef ventricular volumes in human fetal hearts by two-dimensional echocardiographyThe American Journal of Cardiology, 1995
- Cardiac dimensions determined by cross-sectional echocardiography in the normal human fetus from 18 weeks to termThe American Journal of Cardiology, 1992
- Reproducibility of ultrasonic measurement of fetal cardiac haemodynamicsBJOG: An International Journal of Obstetrics & Gynaecology, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Reproducibility of left ventricular volumes by two-dimensional echocardiographyJACC, 1983
- M‐MODE ULTRASONIC ASSESSMENT OF FETAL CARDIOVASCULAR DYNAMICSBJOG: An International Journal of Obstetrics & Gynaecology, 1981
- Reproducibility of echocardiographic estimates of left ventricular dimensions.Heart, 1977
- Problems in echocardiographic volume determinations: Echocardiographic-angiographic correlations in the presence or absence of asynergyThe American Journal of Cardiology, 1976
- Left Ventricular Volumes and Ejection Fraction by EchocardiographyCirculation, 1971