Numerical Investigation of the Temperature Field Evolution of L-Shaped CFST Columns During Water Spray Cooling After Elevated-Temperature Fire Exposure
Open Access
Abstract
To investigate the cooling mechanism and temperature field evolution of L-shaped concrete-filled steel tubular (CFST) columns during post-fire water spray cooling, the ISO-834 standard fire curve was adopted as the fire heating condition. On this basis, the initial temperature field for the cooling stage was established based on fire simulation results for different flame coverage thicknesses. A fluid–structure coupled numerical model that comprehensively accounts for radiation, convection, and conduction was then developed using the computational fluid dynamics (CFD) software Fluent. In addition, the discrete phase model (DPM) was employed to simulate droplet transport and heat mass transfer, and a droplet evaporation model was activated to account for latent heat absorption. Meanwhile, the SST k–ω turbulence model was also adopted to systematically simulate the cooling process of L-shaped CFST columns under different spray positions and spray flow rates. The results indicate that, during the spray cooling process, the spray position and spray flow rate are key factors governing the cooling effectiveness. Owing to the geometric asymmetry of the L-shaped cross-section, different spray positions resulted in markedly different cross-sectional temperature distributions. Among them, Position 3 (outer surface of the horizontal limb) exhibited the best overall cooling performance, with the average cooling rate on the sprayed surface reaching a maximum of 1.011 °C/s; this was followed by Position 1 (outer surface of the vertical limb), whereas Position 2 (internal corner region) exhibited a relatively lower cooling rate. Moreover, an increase in the spray flow rate accelerated the cooling of the sprayed surface and reduced the time required to reach the target temperature. During the initial cooling stage, the concrete core continued to absorb heat from the high-temperature steel tube and adjacent high-temperature regions. When the heat input exceeded the heat output, the internal concrete temperature continued to rise. As cooling proceeded, the concrete temperature began to decrease gradually. The thermal resistance at the steel–concrete interface was primarily responsible for the lag in the concrete temperature response. Within the investigated parameter range, the results can provide a reference for post-fire temperature assessment and spray parameter selection for L-shaped CFST columns.Keywords
This publication has 16 references indexed in Scilit:
- Axial compression performance of concrete-encased CFST columns after exposure to elevated temperature and water coolingStructures, 2025
- Simulation on the spray cooling of a high-temperature cylindrical surfaceInternational Journal of Heat and Mass Transfer, 2024
- Experimental Investigation on Post-fire Response of Concrete-Filled Steel Tube Column Subjected to Elevated TemperatureFire Technology, 2023
- Post-fire bond behaviour in elliptical concrete filled steel tubes: Experiment and simulationJournal of Constructional Steel Research, 2022
- Numerical investigation on the unsteady spray cooling of high temperature steel plateInternational Journal of Heat and Mass Transfer, 2019
- Effect of elevated temperatures and cooling methods on strength of concrete made with coarse and fine recycled concrete aggregatesConstruction and Building Materials, 2019
- Seismic performance of concrete-filled double-skin steel tubes after exposure to fire: ExperimentsJournal of Constructional Steel Research, 2019
- Post-fire residual strength of steel tubular T-joint with concrete-filled chordJournal of Constructional Steel Research, 2017
- Physical-mechanical behavior of concretes exposed to high temperatures and different cooling systemsStructural Concrete, 2017
- Effect of thermal shock due to rapid cooling on residual mechanical properties of fiber concrete exposed to high temperaturesConstruction and Building Materials, 2008