System Accuracy and Interference Evaluation of a New Glucose Dehydrogenase-Based Blood Glucose Meter for Patient Self-Testing
Open Access
- 2 October 2023
- journal article
- research article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (2) , 431-435
Abstract
New European medical device regulations require the performance of postmarketing surveillance evaluations for blood glucose meters (BGMs). We conducted an ISO15197:2015-conform system performance evaluation with the approved glucose dehydrogenase (GDH)-based Wellion NEWTON BGM. One hundred subjects were enrolled into the study (44 female, 56 male, 43 healthy subjects, 23 type 1 diabetes, 34 type 2 diabetes, age: 53.7 ± 15.8 years). In addition, manipulated heparinized whole blood was used for a laboratory interference test with ten selected substances (interference definition: substance-induced bias > 10%). The mean absolute relative difference (MARD) was 4.7%, and 100% of the values were in zones A (99.7%) and B (0.3%), respectively, of the consensus error grid. Interference was observed with xylose only, which is a known interfering substance for GDH-based BGMs.Keywords
Funding Information
- MedTrust GesmbH
This publication has 17 references indexed in Scilit:
- A comprehensive evaluation of strip performance in multiple blood glucose monitoring systemsExpert Review of Medical Devices, 2015
- Technical Aspects of the Parkes Error GridJournal of Diabetes Science and Technology, 2013
- A New Test Strip Technology Platform for Self-Monitoring of Blood GlucoseJournal of Diabetes Science and Technology, 2013
- Significant Insulin Dose Errors May Occur if Blood Glucose Results are Obtained from Miscoded MetersJournal of Diabetes Science and Technology, 2007
- Poor Control of Risk Factors for Vascular Disease Among Adults With Previously Diagnosed DiabetesJAMA, 2004
- A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose.Diabetes Care, 2000
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- One-hour serum xylose as an absorption test in the tropics.Journal of Clinical Pathology, 1981
- Standardised approach to gluten challenge in diagnosing childhood coeliac disease.BMJ, 1976