Abstract
Although patients supported with a Continuous-Flow Left Ventricular Assist Device (CF-LVAD) are hemodynamically stable, their exercise capacity is limited. Hence, the aim of this work was to investigate the underlying factors that lead to peak and submaximal exercise intolerance of CF-LVAD supported patients. Seven months after CF-LVAD implantation, eighty three patients performed a maximal cardiopulmonary exercise test and a six minute walk test. Peak oxygen uptake and the distance walked were measured and expressed as a percentage of the predicted value (%VO2p and %6MWD, respectively). Preoperative conditions, echocardiography, laboratory results and pharmacological therapy data were collected and a correlation analysis against %VO2p and %6MWD was performed. CF-LVAD patients showed a relatively higher submaximal exercise capacity (%6MWD = 64±16%) compared to their peak exertion (%VO2p = 51±14%). The variables that correlated with %VO2p were CF-LVAD parameters, chronotropic response, opening of the aortic valve at rest, tricuspid insufficiency, NT-proBNP and the presence of a cardiac implantable electronic device. On the other hand, the variables that correlated with %6MWD were diabetes, creatinine, urea, ventilation efficiency and CF-LVAD pulsatility index. Additionally, both %6MWD and %VO2p were influenced by the CF-LVAD implantation timing, calculated from the occurrence of the cardiac disease. Overall, both %6MWD and %VO2p depend on the duration of heart failure prior to CF-LVAD implantation. %6MWD is primarily determined by parameters underlying the patient’s general condition, while %VO2p mostly relies on the residual function and chronotropic response of the heart. Moreover, since %VO2p was relatively lower compared to %6MWD, we might infer that CF-LVAD can support submaximal exercise but is not sufficient during peak exertion. Hence concluding that the contribution of the ventricle is crucial in sustaining hemodynamics at peak exercise.Keywords
Funding Information
- KU Leuven (C14/18/080)
This publication has 38 references indexed in Scilit:
- Chronotropic Incompetence May Impact Exercise Capacity in Patients Supported by Left Ventricular Assist DeviceThe Journal of Heart and Lung Transplantation, 2013
- Combining neurohormonal blockade with continuous-flow left ventricular assist device support for myocardial recovery: A single-arm prospective studyThe Journal of Heart and Lung Transplantation, 2013
- Usefulness of the Six-Minute Walk Test After Continuous Axial Flow Left Ventricular Device Implantation to Predict SurvivalThe American Journal of Cardiology, 2012
- Predicting Maximal HR in Heart Failure Patients on β-Blockade TherapyMedicine & Science in Sports & Exercise, 2012
- Central and Peripheral Blood Flow During Exercise With a Continuous-Flow Left Ventricular Assist DeviceCirculation: Heart Failure, 2011
- Exercise Capacity in Patients Supported With Rotary Blood Pumps Is Improved by a Spontaneous Increase of Pump Flow at Constant Pump Speed and by a Rise in Native Cardiac OutputArtificial Organs, 2011
- Standards for the use of cardiopulmonary exercise testing for the functional evaluation of cardiac patients: a report from the Exercise Physiology Section of the European Association for Cardiovascular Prevention and RehabilitationEuropean Journal of Preventive Cardiology, 2009
- Which Factors Predict the Recovery of Natural Heart Function After Insertion of a Left Ventricular Assist System?The Journal of Heart and Lung Transplantation, 2008
- Six-minute walking performance in patients with moderate-to-severe heart failure; is it a useful indicator in clinical practice?European Heart Journal, 2001
- The Six-Minute Walk Test Predicts Peak Oxygen Uptake and Survival in Patients With Advanced Heart FailureChest, 1996