Comparing Surface and Intramuscular Electromyography for Simultaneous and Proportional Control Based on a Musculoskeletal Model: A Pilot Study
Authors:
- Dustin L. CrouchDCDustin L. Crouch
- Lizhi PanLPLizhi Pan
- William FilerWFWilliam Filer
- Jonathan W. StallingsJSJonathan W. Stallings
- He HuangHHHe Huang
- 1 September 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 26 (9) , 1735-1744
Abstract
Simultaneous and proportional control (SPC) of neural-machine interfaces uses magnitudes of smoothed electromyograms (EMG) as control inputs. Though surface EMG (sEMG) electrodes are common for clinical neural-machine interfaces, intramuscular EMG (iEMG) electrodes may be indicated in some circumstances (e.g., for controlling many degrees of freedom). However, differences in signal characteristics between sEMG and iEMG may influence SPC performance. We conducted a pilot study to determine the effect of electrode type (sEMG and iEMG) on real-time task performance with SPC based on a novel 2-degree-of-freedom EMG-driven musculoskeletal model of the wrist and hand. Four able-bodied subjects and one transradial amputee performed a virtual posture matching task with either sEMG or iEMG. There was a trend of better task performance with sEMG than iEMG for both able-bodied and amputee subjects, though the difference was not statistically significant. Thus, while iEMG may permit targeted recording of EMG, its signal characteristics may not be as ideal for SPC as those of sEMG. The tradeoff between recording specificity and signal characteristics is an important consideration for development and clinical implementation of SPC for neural-machine interfaces.Keywords
Funding Information
- Defense Advanced Research Projects Agency (N66001-16-2-4052)
- National Science Foundation (1527202, 1637892)
- DHHS/NIDILRR (90IF0064)
- U.S. Department of War (W81XWH-15-C-0125, W81XWH-15-1-0407)
This publication has 40 references indexed in Scilit:
- A Training Strategy for Learning Pattern Recognition Control for Myoelectric ProsthesesJPO Journal of Prosthetics and Orthotics, 2013
- The Usefulness of Mean and Median Frequencies in Electromyography Analysis2012
- Patient Training for Functional Use of Pattern Recognition–Controlled ProsthesesJPO Journal of Prosthetics and Orthotics, 2012
- Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial ArmsJAMA, 2009
- Effect of Training on Upper-Extremity Prosthetic Performance and Motor Learning: A Single-Case StudyArchives of Physical Medicine and Rehabilitation, 2008
- Mapping phantom movement representations in the motor cortex of amputeesBrain, 2006
- Direct neural sensory feedback and control of a prosthetic armIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2005
- A robust, real-time control scheme for multifunction myoelectric controlIEEE Transactions on Biomedical Engineering, 2003
- Intramuscular and surface EMG power spectrum from dynamic and static contractionsJournal of Electromyography and Kinesiology, 1995
- A new strategy for multifunction myoelectric controlIEEE Transactions on Biomedical Engineering, 1993