Combined estimation of B1 and T1 for dynamic contrast-enhanced MRI by accounting for incomplete spoiling of transverse magnetization
Authors:
- 28 March 2023
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (3) , 037002
Abstract
Objective. The variable flip angle (VFA) method for longitudinal relaxation time (T 1) measurement is inherently sensitive to inaccuracies in the radiofRequency transmit field (B 1) and incomplete spoiling of transverse magnetization. The objective of this study is to devise a computational method that addresses the problems of incomplete spoiling and B 1 inhomogeneity in the estimation of T 1 using VFA method. Approach. Using an analytical expression of the gradient echo signal with account of incomplete spoiling, we first showed that ill-posedness in the simultaneous estimation of B 1 and T 1 can be lifted with the use of flip angles larger than the Ernst angle. We then devised a nonlinear optimization method based on this signal model of incomplete spoiling for simultaneous estimation of B 1 and T 1. Main results. We evaluated the proposed method on a graded-concentration phantom to show that the derived T 1 estimates offers an improvement over the regular VFA method and compares well with reference values measured by inversion recovery. Reduction of the number of flip angles from 17 to 5 yielded consistent results indicating that the proposed method is numerically stable. T 1 estimates derived from in-vivo brain imaging were consistent with literature values for gray and white matter tissues. Significance. Contrary to the common notion that B 1 correction in the VFA method for T 1 mapping should be performed separately, we show that combined estimation of B 1 and T 1 is feasible by the proposed method simply with the acquisition of 5 flip angles, as demonstrated on both phantom and in-vivo imaging data.Keywords
This publication has 43 references indexed in Scilit:
- Fundamentals of tracer kinetics for dynamic contrast‐enhanced MRIJournal of Magnetic Resonance Imaging, 2011
- Mapping of low flip angles in magnetic resonancePhysics in Medicine & Biology, 2011
- Optimization and validation of methods for mapping of the radiofrequency transmit field at 3TMagnetic Resonance in Medicine, 2010
- B1 mapping by Bloch‐Siegert shiftMagnetic Resonance in Medicine, 2010
- High‐resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high‐speed incorporation of RF field inhomogeneities (DESPOT1‐HIFI)Journal of Magnetic Resonance Imaging, 2007
- Optimized and combined T1 and B1 mapping technique for fast and accurate T1 quantification in contrast‐enhanced abdominal MRIMagnetic Resonance in Medicine, 2007
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- Relaxation. Can T2, be longer than T1?Concepts in Magnetic Resonance, 1991
- T 2 can be greater than 2T1 even at finite temperatureThe Journal of Chemical Physics, 1991
- FLASH imaging. Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance (1969), 1986